(2)
LBA mode
Logical address assignment in the LBA mode starts from physical cylinder 0, physical head 0, and
physical sector 1. The logical address is advanced at the subsequent sector from the last sector of
the current track. The first physical sector of the subsequent physical track is the consecutive
logical sector from the last sector of the current physical track.
Figure 6.6 shows an example of (assuming there is no track skew).
Physical sector
1
Physical cylinder 0
LBA
Physical head 0
1
Physical cylinder 0
LBA
608
Physical head 1
ex: Zone 0
Physical parameter
- Physical sector: 1 to 592 (For the rest, 2 spare sectors)
Figure 6.6
6.3
Power Save
The host can change the power consumption state of the device by issuing a power command to
the device.
6.3.1
Power save mode
There are four types of power consumption state of the device including active mode where all
circuits are active.
In the power save mode, power supplying to the part of the circuit is turned off. There are three
types of power save modes:
Idle mode
Standby mode
Sleep mode
6 - 8
2
3
. . . . . . . . . . . . . . . . . . . . . .
LBA
LBA
0
1
2
. . . . . . . . . . . . . . . . . . . . . .
2
3
. . . . . . . . . . . . . . . . . . . . . .
LBA
LBA
609
610
. . . . . . . . . . . . . . . . . . . . . .
Address translation (example in LBA mode)
C141-E112-01EN
605
606
607
608
LBA
LBA
LBA
LBA
604
605
606
607
605
606
607
608
LBA
LBA
LBA
LBA
1212
1213
1214
1215