Current Requirements and Power Dissipation
Table 1.3 lists the current and power dissipation.
Mode of Operation
Model
MPE
3102AH
Spin up
1600
1800 peak
Idle (Ready)
340
(*3)
R/W (On Track)
340
(*4)
Seek (Random)
640
(*5)
Standby
7.0
Sleep
7.0
*1 Current is typical rms except for spin up.
*2 Power requirements reflect nominal values for +12V and +5V power.
*3 Idle mode is in effect when the drive is not reading, writing, seeking, or executing any commands. A portion of the R/W circuitry is powered
down, the spindle motor is up to speed and the Drive ready condition exists.
*4 R/W mode is defined as 50% read operations and 50% write operations on a single physical track.
*5 Seek mode is defined as continuous random seek operations with minimum controller delay.
1 - 6
Table 1.3

Current and power dissipation

Typical RMS current (*1) [mA]
+12 V
MPE
MPE
MPE
3136AH
3204AH
3273AH
1600
1600
1600
1800 peak
1800 peak
1800 peak
340
400
460
340
400
460
640
670
700
7.0
7.0
7.0
7.0
7.0
7.0
C141-E090-01EN
Typical Power (*2) [watts]
+5 V
All
MPE
MPE
Models
3102AH
3136AH
540
21.9
21.9
640 peak
420
6.2
6.2
450
6.3
6.3
420
9.8
9.8
185
1.0
1.0
185
1.0
1.0
MPE
MPE
3204AH
3273AH
21.9
21.9
6.9
7.6
7.1
7.8
10.1
10.5
1.0
1.0
1.0
1.0