3.
Click Setup → Group Administration.
4.
In the Chassis Group page, under Role, select None, and then click Apply.
The lead chassis then communicates to all the members that they have been removed from the group. The lead
chassis can be assigned as a leader or member of a new group.
If a network issue prevents contact between the leader and the member, the member chassis may not receive the
message. In this case, disable the member from the member chassis to complete the removal process.

Disabling an Individual Member at the Member Chassis

Sometimes a member cannot be removed from a group by the lead chassis. This can happen if network connectivity to
the member is lost. To remove a member from a group at the member chassis:
1.
Log in with chassis administrator privileges to the member chassis.
2.
In the left pane, click Chassis Overview → Setup → Group Administration.
3.
Select None, and then click Apply.

Launching the Web page of a Member Chassis or Server

You can access the web page of the member chassis, remote console of the server, or the web page of the iDRAC
server from the lead chassis group page. If the member device has the same login credentials as the lead chassis, you
can use the same credentials to access the member device.
To navigate to member devices:
1.
Log in to the lead chassis.
2.
Select Group: name in the tree.
3.
If a member CMC is the required destination, select Launch CMC for the required chassis.
If a server in a chassis is the required destination:
a) Select the image of the destination chassis.
b) In the chassis image that appears in the Health section, select the server.
c) In the box labeled Quick Links, select the destination device. A new window is displayed with the destination
page or login screen.

Synchronizing a New Member With Leader Chassis Properties

You can apply the properties from the leader to a newly added member chassis of a group. To synchronize a new
member with the leader properties:
1.
Log in with administrator privileges to the leader chassis.
2.
Select the lead chassis in the tree structure.
3.
Click Setup → Group Administration.
4.
While adding a new member to the group, in the Chassis Group page, select Sync New Member with Leader
Properties.
5.
Click Apply. The member takes on the properties of the leader.