3. Select [Fix] or [Redundancy Check] from the [Policy] pull-down menu.
Fix:
Redundancy Check: If an inconsistency error is detected, the process is continued
4. Select the [Enable] radio button in the schedule setting field below [Scheduled].
If the schedule setting field does not appear, click the green triangle mark to the left of
[Scheduled] to display the field.
5. Set the time at which the synchronization is started.
The details of the settings are as follows:
By Day
Synchronization is started at the defined time everyday.
By Week
Synchronization is started on the defined day of every week.
By Month Synchronization is started on the defined date every month.
6. If the setting is completed, click [Schedule].
After the scheduling, "Scheduled Successfully" appears at the top of the tab.
The scheduling is completed in the above procedure.
The scheduled synchronization can be checked by the Schedule tab of the Controller icon. See
"3.6.1 Controller" for details.
Synchronization is started at the defined time and repeated at the interval entered in step 3.
To cancel (delete) the scheduling, click the Schedule tab of Controller, click the [Select]
checkbox you want to delete, and click [Delete].
NOTE: Synchronization can be done for a specific
logical drive independently. Click the Logical Drive icon
in the Tree View and schedule synchronization in the
Synchronization tab.
If an inconsistency error is detected, data is repaired from the
other mating disk configuring the RAID.
without repair of the error.
-
-