3.6.6 Cleaning or Replacing a Combustion Air Blower
A sheet metal shield or shield assembly prevents inadvertent access to the blower assembly. The
specific design varies depending upon the particular configuration of the fryer and the country for
which manufactured, but in all cases, the shield is attached to the cabinet framing by sheet metal
screws. Remove the screws that secure the shield or shield assembly to the cabinet framing and pull
the shield out of the fryer to expose the combustion air blower assembly.
1. Disconnect the blower wiring harness and remove the blower assembly mounting nuts.
2. Remove the three fasteners that secure the blower motor assembly to the blower housing, and
separate the two components.
Blower
assembly
Wiring connection
mounting
3-11
nuts
Remove these fasteners.
(On black-colored FASCO
blowers there are three
nuts. On silver-colored
KOOLTRONICS blowers
there are three screws.)