Download Print this page

Frymaster CF Series Installation And Operation Manual page 33

Cf series gas fryers

Advertisement

5. Remove the Power Shower and allow it to
drain. Ensure the drain valve is fully closed
(arrow). Turn the fryer ON and allow the oil
to reach setpoint.
NOTE: Ensure the fryer drain valve is
fully closed before turning the fryer on. If
the drain valve is not fully closed, the
controller will display an error message or
a trouble light and the fryer will not
operate.
The filter pump is equipped with a manual reset switch in case the filter motor
overheats or an electrical fault occurs. If the thermal overload switch trips, turn off
power to the filter system and allow the pump motor to cool 20 to 45 minutes before
CF SERIES GAS FRYERS
CHAPTER 4: FILTRATION INSTRUCTIONS
WARNING
attempting to reset the switch.
Drain handle in the
closed position.
4-8

Advertisement

loading

This manual is also suitable for:

FmcfFmcfeFmcfecMjcfMjcfeMjcfec ... Show all