Installation Manual of Room Air Conditioner

Preparation
Necessary Tools for Installation
Hammer
Nipper
Hacksaw
Hole core drill
Spanner(17,19 and 26mm)
Gas leakage detector or
soap-and-water solution
Power Source
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be
reached.Do not extend the cable by cutting it.
Drawing for the installation of indoor and outdoor units
The models adopt HC FC free refrigerant R410A
more than 10cm
(3 7/8)
more than
10cm (3 7/8)
Arrangement of piping
directions
Rear left
Rear
Left
right
Right
Below
more than 20cm
The marks from
to
A
in the gure are the
G
parts numbers.
The distance between
the indoor unit and the
oor should be more
than 2m.
more than 60cm
(23 5/8)
The above picture is for your reference only. Your product may look different.
Read this manual before installation.
Explain the operation of the unit to the user according to this manual.
NO.0010536242
HSU
Torque wrench
(17mm,22mm,26mm)
Pipe cutter
Flaring tool
Knife
Measuring tape
Reamer
Attention must be paid to
the pitch of drain hose
more than 10cm
more than 15cm
(7 7/8)
VHJ(DB)-SM
Selection of Installation Place
Indoor Unit - Select a location that is
Robust not causing vibration, where the body can be supported s
Not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
Possible to drain easily, where piping can be connected with the outdoor unit.
Where cold air can be spread in a room evenly.
Nearby a power receptacle. (Refer to drawings).
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and uorescent lamps can be left.
In the case of xing the remote controller on a wall, place where the indoor unit can
receive signals when the uorescent lamps in the room are in use.
Outdoor Unit - Select a location that is
Strong enough to bear the unit, where vibration and noise are not increased.
Not causing a nuisance to neighbors due to discharged air or noise.
A distance marked
?
is available as illustrated in the below gure.
G
(3 7/8)
F
A
C
(5 7/8)
D
E
more than 25cm
(9 7/8)
tilated.
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Floor xing dimensions of the
outdoor unit
(Unit:mm / inch)
For:09k 12k 18k
140
500
140
(5 1/2)
(19 2/3)
(5 1/2)
For:24k
113.5
633
113.5
(4 1/2)
(24 7/8)
(4 1/2)
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts (10mm) and nuts rmly
and horizontally.
When tting the unit to wall
surface, roof or rooftop, x
a supporter securely with nails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
house, x the unit by attaching a
vibration-proof mat.