Installation Manual of Room Air Conditioner

Preparation
Necessary Tools for Installation
Hammer
Nipper
Hacksaw
Hole core drill
Spanner(17,19 and 26mm)
Gas leakage detector or
soap-and-water solution
Power Source
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be
reached.Do not extend the cable by cutting it.
Drawing for the installation of indoor and outdoor units
The models adopt HC FC free refrigerant R410A
more than 10cm
(3 7/8)
more than
10cm (3 7/8)
Arrangement of piping
directions
Rear left
Rear
Left
right
Right
Below
more than 20cm
The marks from
to
A
in the figure are the
G
parts numbers.
The distance between
the indoor unit and the
floor should be more
than 2m.
more than 60cm
(23 5/8)
The above picture is for your reference only. Your product may look different.
Read this manual before installation.
Explain the operation of the unit to the user according to this manual.
NO.00105
Torque wrench
(17mm,22mm,26mm)
Pipe cutter
Flaring tool
Knife
Measuring tape
Reamer
Attention must be paid to
the pitch of drain hose
more than 10cm
more than 15cm
(7 7/8)
Selection of Installation Place
Indoor Unit - Select a location that is
Robust not causing vibration, where the body can be supported sufficiently.
Not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
Possible to drain easily, where piping can be connected with the outdoor unit.
Where cold air can be spread in a room evenly.
Nearby a power receptacle. (Refer to drawings).
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent lamps in the room are in use.
Outdoor Unit - Select a location that is
Less affected by rain or direct sunlight and is sufficiently ventilated.
Strong enough to bear the unit, where vibration and noise are not increased.
Not causing a nuisance to neighbors due to discharged air or noise.
Q
A distance marked
is available as illustrated in the below figure.
G
(3 7/8)
F
A
C
(5 1/2)
(5 7/8)
(4 1/2)
D
E
more than 25cm
(9 7/8)
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Floor fixing dimensions of the
outdoor unit
(Unit:mm / inch)
For:09k 12k 18k
140
500
140
(19 2/3)
(5 1/2)
For:24k
113.5
633
113.5
(24 7/8)
(4 1/2)
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts (10mm) and nuts firmly
and horizontally.
When fitting the unit to wall
surface, roof or rooftop, fix
a supporter securely with nails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
house, fix the unit by attaching a
vibration-proof mat.

Advertisement

Table of Contents
loading

Summary of Contents for Haier Room Air Conditioner

  • Page 1: Installation Manual Of Room Air Conditioner

    Installation Manual of Room Air Conditioner Preparation Selection of Installation Place Necessary Tools for Installation Indoor Unit - Select a location that is Torque wrench Hammer (17mm,22mm,26mm) Nipper Robust not causing vibration, where the body can be supported sufficiently. Hacksaw...
  • Page 2: Indoor Unit

    [ Left Left-rear piping ] Accessory parts In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to Drain hose (1) Remote controller (1) the mark of hole for left-rear piping which is marked on heat insulation materials.
  • Page 3: Outdoor Unit

    Ensure that no dirt or debris enters the pipe. Outdoor unit The standard pipe length is 7m (27 9/16) . If it is over 7m (27 9/16) , the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should Indoor uni t be charged, according to 20 g/m (0.018 oz/inch).
  • Page 4 No gas leakage? On Drainage In case of gas leakage, tighten parts of pipe connection. If leakage stops, Please install the drain hose so as to be downward slope without fail. then proceed step 6. If leak continues, remove the refrigerant used for the Please don’t do the drainage as shown below.
  • Page 5: Fuente De Alimentación

    Manual de instalación de aparato de aire acondicionado Preparación Herramientas necesarias para realizar la instalación Selección del lugar de instalación Unidad interior – Elija una ubicación que sea Martillo Llave dinamométrica (17 mm, 22 mm, 26 mm) ● Firme y que no provoque vibraciones, que pueda soportar la unidad adecuadamente. Alicate ●...
  • Page 6: Unidad Interior

    [Izquierda • Entubación trasera izquierda] Accesorios En caso de realizar la entubación por el lado izquierdo, corte con una cuchilla la cubierta de la entubación izquierda. En caso de realizar la entubación a través de la parte trasera izquierda, doble los Control remoto (1) Manguera de drenaje (1) tubos de acuerdo con la dirección de entubación que figura en la marca del orificio...
  • Page 7: Unidad Exterior

    Asegúrese de que no penetren residuos o suciedad en el tubo. Unidad exterior La longitud estándar del tubo es de 7m . Si el tubo tiene más de 7m (27 9/16) (27 9/16) se verán afectadas las funciones de la unidad. Si es necesario alargar el tubo, deberá Unidad interior cargarse refrigerante adicional a razón de 20 g/m (0.018 oz/pulgada)
  • Page 8 5. ¿No existen fugas de gas? 1. Cortar el tubo 2. Eliminar las rebabas Cuchilla de conicidad En caso de que exista una fuga de gas, apriete las conexiones de los tubos. Si la fuga se detiene, proceda al paso 6. 3.
  • Page 9 Manuel d'installation d'un climatiseur de pièce Préparation Outillage requis pour l'installation Sélection de l'emplacement pour l'installation Unité intérieure – Sélectionnez un emplacement qui soit Marteau Clé dynamométrique (17 mm, 22 mm, 26 mm) Pince ● Solide sans vibration et offrant un support suffisant. ●...
  • Page 10: Unité Intérieure

    Accessoires [Gauche • Tuyauterie arrière gauche] Dans le cas d'une tuyauterie à gauche, découpez, avec une pince, le couvercle pour la tuyauterie gauche. Télécommande (1) Tuyau de vidange (1) Pour une tuyauterie à l'arrière gauche, cintrez les tuyaux selon le sens de la tuyau- terie jusqu'à...
  • Page 11: Unité Extérieure

    Assurez-vous qu'aucune impureté ni débris ne sont entrés dans le tuyau. Unité extérieure La longueur standard du tuyau est de 7 m . Au delà de 7 m , l'unité (27 9/16) (27 9/16) ne fonctionnera pas correctement. S'il faut rallonger le tuyau, le réfrigérant doit être chargé...
  • Page 12 5. Pas de fuite de gaz? Correct Incorrect En cas de fuite de gaz, resserrez les pièces de connexion du tuyau. Lorsque la fuite est maîtrisée, passez à l'étape 6 Insuffisant Evasement endommagé Fissure Partiel Vers extérieur Vidange 6. Détachez le tuyau de charge de l'orifice d'entretien, ouvrez la vanne à 2 et 3 voies. Tournez le robinet de la vanne dans le sens antihoraire.

Table of Contents