Haier HSU24VHJ(DB) Service Manual page 79

Wall mounted type dc inverter ea-series
Hide thumbs Also See for HSU24VHJ(DB):
Table of Contents

Advertisement

9.16 Removal of Electrical Box
Procedure
Step
Remove the front grille.
1. Remove the electrical
box.
Loosen the screw of the
1
drip proof plate.
2
Lift and remove the drip
proof plate.
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Points
Discharge the static
electricity from your body
before touching the electrical
parts like signal receiver
PCB.
It may cause malfunction of
PCB.
Domestic air conditioner

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hsu24vhj

Table of Contents