Horizontal Terminations for All Fluing Systems
The shaded areas in the diagram below show all allowable combina-
tions of vertical runs with horizontal terminations. Maximum one
90
O
elbow (two 45
o
elbows equal one 90
LPG and NG:
Residential, Manufactured and Mobile
Homes Installations
The fl uing arrangements diagrammed below, have a min. of 75% (fl ue
loss) effi ciency with Fan Off, as required for manufactured homes. (Actual
effi ciency may be as high as 85%)
May be installed in Manufactured (Mobile) Homes after fi rst sale.
To set the Flue restriction as indicated in the diagram, simply loosen the
screws and push the fl ue restrictor plate to the correct position. Tighten
the screws.
Regency
®
F39 Room Sealed Freestanding Gas Stove

FLUING ARRANGEMENTS

o
elbow).
Flue Restrictor Position
Vertical Terminations Using
Dura-Flue Fluing System for
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable combi-
nations of straight vertical and offset to vertical runs with vertical
terminations. Maximum two 45
If the fl ue is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4"
clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after fi rst sale.
Flue Restrictor setting at
40 Mj/h
INSTALLATION
o
elbows.
Flue Restrictor setting at
31 Mj/h