MAINTENANCE
7) Tighten side panels nuts using the following
procedure:
a. tighten top & bottom outside corner nuts
(2)
b. tighten inside nuts (3)
c. tighten top & bottom inside corners (2)
8) Tighten the 10 nuts on center glass re-
tainer.
9) Repeat step 7 for other side panel.
10) Replace new gasket by gluing it in place.
11) Install door onto stove and check the seal.

FAN MAINTENANCE

If your fan requires maintenance or replacement,
access to the fan is through the plate on the rear
wall of the fi rebox. NOTE: the unit MUST NOT
be operated without the fan access panel
securely in place and correctly sealed.
If the fan is damaged or needs repair, it
shall be repaired by the manufacturer or its
service agent or similiarily qualifi ed person
to avoid a hazard.
IMPORTANT: These fans collect a lot of
dust from within your home. Ensure
you maintain these fan motors on a
regular basis by vacuuming out the
fan squirrel cages, around the motor,
and around the grills on the back of
the stove.
IMPORTANT
Disconnect power supply
before servicing
WARNING:
Electrical Grounding Instruc-
tions
This appliance is equipped with
a three pronged (grounding) plug
for your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle. Do not cut
or remove the grounding prong
from this plug.
26
To remove F39 fan:
1) Unplug or disconnect power source to
stove.
2) Remove all logs and the rear log support,
then remove the 10 screws holding the ac-
cess panel in place.
3) Unclip the black and white wires from the
fan motor.
4)
Open both side doors and gently pull the
fl ex pipe away from the center, otherwise
the fan can catch on the fl ex pipe during
installation and tear the pipe. Do not tear
or damage the fl ex pipe.
Alternate Fan Access:
If the rear access cover is ac-
cessible, it can be removed to
provide access to the fan.
5) Lift fan off of the 2 pins, tip back and pull
through fi rebox opening. Disconnect the
green ground wire from the right side of the
fan as soon as you can reach it.
Replacing F39 Fan:
Reverse the above steps (1 - 5). If necessary
install a new gasket before replacing the fan
access panel. Make sure the fan wires and the
ground wire are reattached.
Hint for pushing fan down onto pins - rub a
bit of dish soap on the grommet so it will slide
more easily onto the pin. Check to make sure
the fan is seated properly on the pins - try to
move the fan back and forth, there should be
no noise, if there is check that the grommets
haven't come loose.