Aeration Adjustment - Regency F39-NG Owners & Installation Manual

Freestanding gas stove
Table of Contents

Advertisement

INSTALLATION
Note: To properly check gas pressure, both
inlet and manifold pressures should
be checked using the valve pressure
ports on the valve.
1) Make sure the valve is in the "OFF" posi-
tion.
2) Loosen the "IN" and/or "OUT" pressure
tap(s), turning counterclockwise with a 1/8"
wide fl at screwdriver.
3) Attach manometer to "IN" and/or "OUT"
pressure tap(s) using a 5/16" ID hose.
4) Light the pilot and turn the valve to "ON"
position. Read manometer.
5) The pressure check should be carried out
with the unit burning and the setting should
be within the limits specifi ed on the safety
label.
6) When fi nished reading manometer, turn
off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8" fl at
screwdriver. Note: Screw should be snug,
but do not over tighten
Valve Description
1) Gas on/off knob
2) Manual high/low adjustment
3) Pilot Adjustment
4) Thermocouple Connection
5) Main Operator
6) Outlet Pressure Tap (Manifold
Pressure)
7) Inlet Pressure Tap (Supply
Pressure)
8) Pilot Outlet
9) Main Gas Outlet
10) Flange Securing Screw Holes
11) Alternative TC Connection Point
12) Thermoelectric Unit
13) Additional Valve Mounting Hole
16
System Data
F39 with 40mj
Burner Inlet Orifi ce Sizes:
NG
Burner
#32
2.95mm
Max. Input NG
40 Mj/h
LPG
38 Mj/h
Min. Input NG
20 Mj/h
LPG
19 Mj/h
Supply Pressure
NG
min. 1.13 kPa
LPG
min. 2.75 kPa
Manifold Pressure
NG
.94 kPa
LPG
2.55kPa
Electrical: 240 V. 1.13A 60Hz.
Circulation: 2 speed fan, 125/75 CFM.
Log Set: Ceramic fi ber, 7 per set.
System Data
F39 Converted to 31mj
Burner Inlet Orifi ce Sizes:
NG
#37 2.65mm
LPG
#52 1.6mm
Max. Input - NG/LPG
31 Mj/h
Min. Input - NG/LPG
16 Mj/h
Supply Pressure
NG
min. 1.13 kPa
LPG
min. 2.75 kPa
Manifold Pressure
NG
.89 kPa
LPG
2.55kPa
Electrical: 240 V. 1.13A 60Hz.
Circulation: Variable speed fan, 125/75
CFM.
Log Set: Ceramic fi ber, 7 per set.
AERATION
ADJUSTMENT
The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude.
F39 with 40mj
F39-NG
F39-LPG
F39 with 31mj
F39-NG
F39-LPG
LPG
#50
1.78mm
Note: Any damage due to carboning resulting
from improperly setting the aeration
controls is NOT covered under war-
ranty.
Regency
®
F39 Room Sealed Freestanding Gas Stove
NG:
Full open
LPG:
Full open
NG
6mm open
LPG
10mm open

Advertisement

Table of Contents
loading

This manual is also suitable for:

F39-lpg

Table of Contents