Removing Valve - Regency F39-NG Owners & Installation Manual

Freestanding gas stove
Table of Contents

Advertisement

If your valve requires maintenance or replace-
ment, use the following instructions:
Note: Always close off the gas supply
before removing the valve.
1) Open front pedestal door. You may want
to put a soft cloth on the base of the unit
so that when the pedestal door is open it
doesn't scratch the paint.
2) Undo the six screws holding the control
panel in place.
3) Disconnect all wires from the back of the
panel and then remove panel. You should
lay the panel on a soft cloth so it doesn't get
marked up. See diagram below.
Regency
®
F39 Room Sealed Freestanding Gas Stove

REMOVING VALVE

4) Remove the two outside frame pieces by
removing two screws per side. See diagram
below.
5) At this point you should disconnect the gas
at the valve. You can access it through the
front now that the control panel is off, or you
can access it through the rear pedestal cover
plate.
6) Carefully remove the logs and lava rock.
7) Remove burner.
Note: Use a magnetic type screwdriver if
possible.
8) Remove all 18 screws holding the burner
tray assembly in place.
9) Carefully lift the burner tray assembly out.
MAINTENANCE
10) To replace the burner tray assembly, simply
reverse these instructions.