SIEMENS 5930/5935 Business Gateway
User's Guide

Internal Modem

The following Dial Backup Configuration page is displayed during Dial Backup configuration if you selected
Internal Modem for the connection.
To configure the internal modem for dial backup:
1. In Backup Failover Timeout, enter the number of minutes that must pass during a WAN link failure before
switching to the backup port. This guards against too frequent switching back and forth between the WAN
link and the backup port. The default minutes is 3.
2. In Retry WAN Timer, enter the number of minutes that must pass before checking to see if the Wan line
has been restored.
3. IP Addresses lists the addresses the router uses to ping via the WAN link. If the ping tests fail, the router
switches data traffic to the backup port until the retry period expires again.
4. In Ping Success Rate, enter the ping success rate that must be met. As soon as the success rate falls
below this number, Wan link failure is assumed and switch over to backup is performed. This success rate
applies to all addresses in the IP Addresses list.
5. In Modem Dial String, select Tone Dialing or Pulse Dialing to control how the modem is dialed.
6. Click Save and Reboot.
SIEMENS
Chapter 5 Advanced Setup
Dial Backup
48