5. In Source IP, select one of the following:
From/To: Enables source address checking. Specify the source IP address or range of IP addresses
that must match for this policy to be used.
Do not care: Disables source address checking.
6. In Dest IP, select one of the following:
From/To: Enables destination address checking. Specify the destination IP address or range of IP
addresses that must match for this policy to be used.
Do not care: Disables destination address checking.
7. In Protocol, select one of the following:
By number: Enter the protocol number to match in the protocol check.
Drop-down menu: Select the protocol to match in the protocol check (TCP or UDP).
Do not care: Disables protocol checking.
8. In Source Port, select one of the following:
From/To: Enter the source port or range of source ports to match in the source port check.
Drop-down menu: Select the application to match in the source port check.
Do not care: Disables source port checking.
9. In Destination Port, select one of the following:
From/To: Enter the destination port or range of destination ports to match in the destination port check.
Drop-down menu: Select the application to match in the destination port check.
Do not care: Disables destination port checking.
10. Select the priority to place on this policy if match criteria is met. This can be Normal, Low, Medium, or
High. Normal is the default.
11. In Code Point - incoming and Code Point - outgoing, select one of the following:
Click the button next to the box to specify the Code Point. Be sure to enter the Code Point in the
appropriate field.
Click Default to accept the default Code Point.
12. In Bidirection, select one of the following:
On: Enables bidirectional operation of the policy.
Off: Disables bidirectional operation of the policy.
13. In Start Time, specify the time of day when the policy becomes active.
14. In Duration, specify the time period for the policy to remain active.
15. In Repetition, select one of the following:
Always on: Policy is applied every day.
At: Policy is applied only one time on the specified month (MM), day (DD), and year (YY).
Every: Policy is applied on the specified day of the week.
16. Click Save.