INTRODUCTION
The VIP-810 networked station port allows most loop
start terminal devices to be connected to a managed
IP-based Local area network (LAN) or Wide area
network (WAN).

SPECIFICATIONS

Access Methods
PBX, FXO Port
POTS telephone set
Features
RJ-45 for network connection
RJ-11 telephone connection
Front panel activity LED
Network activity LEDs on RJ-45
4 RENS
2.5mm jack for DC power (115VAC TO 24VDC
adapter provided)
Dimensions/Weight
• 1.88" H x 5.50" W x 4.15" D
(4.78cm H x 13.97cm W x 10.54cm D)
• Weight: 0.55 lbs. (0.25 kg)
Nominal Specifications
Input Impedance:
Input Level:
Output Impedance:
Output Level:
Nominal Power Requirements
Voltage:
Current:
Environment
Temperature:
Humidity:
VIP-810
NETWORKED STATION PORT
600 Ohms
-10dBm
600 Ohms
- 10dBm nominal
24VDC
325mA
0 to +40°C
0 to 85% non-precipitating
INSTALLATION
NOTE: The telephone system referred to in this
manual is the customer premise equipment such
as an electronic key system, a PBX or a dedicated
single line telephone sets. The VIP-810 is not
intended for direct or indirect connection to the
public telephone network. When used with a
customer premise telephone system such as a
key system or PBX system, these units are
interfaced to the system via a fully protected loop
start trunk (FXO) port. Also, the host system
must be configured to disallow central office
trunk conferencing in order to prevent indirect
connection to the public network.
Precautionary Designations
CAUTION
RISK OF ELECTRIC SHOCK
CAUTION: To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
Refer servicing to qualified service personnel.
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
1
ISSUE 3
DO NOT OPEN
947052

Advertisement

loading
Need help?

Need help?

Do you have a question about the IP Solutions VIP-810 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Valcom IP Solutions VIP-810

  • Page 1: Specifications

    ISSUE 3 VIP-810 NETWORKED STATION PORT INTRODUCTION The VIP-810 networked station port allows most loop start terminal devices to be connected to a managed IP-based Local area network (LAN) or Wide area network (WAN). SPECIFICATIONS INSTALLATION Access Methods NOTE: The telephone system referred to in this •...
  • Page 2: Power Connections

    APPLICATION EXAMPLES Use the VIP-810 with a PBX Loop Start Trunk Port and a VIP-800 to interface the telephone system to Valcom powered speakers over a network. When the PBX Loop Start Trunk Port is accessed, the VIP-810 will activate the VIP-800.
  • Page 3 In this example, the VIP-810 and VIP-820 are connected to the data network to extend the station port to a remote Door Phone . This could be installed where network access is available, but not telephone wiring. When initiating a call from the VIP-820 an open loop, disconnect signal is required from the PBX Station Port.
  • Page 4 This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation or use of the product.