Troubleshooting - Bosch DAF220 Original Instructions Manual

Miterfinder
Table of Contents

Advertisement

Available languages

Available languages

daf220_bu_2609140572_003.fm Seite 19 Montag, 8. September 2008 2:22 14

Troubleshooting

Issue
Remedy
Noise is
No action typically
coming
required. The sound
from area
is from the motor is
between
used to measure
the tool's
the angle between
legs
the legs.
MTR value
The Miterfinder pro-
doesn't
vides miter angle
correspond
values for saws with
to the miter
miter scales that
scale on a
have 0° as the set-
particular
ting for a perpen-
saw.
dicular cut.
When making miter
cuts on tools that
have 90° as the per-
pendicular cut set-
ting, the MTR angle
provide by the
Miterfinder needs
to be subtracted
from 90°.
It is not
Follow the saw's
clear as to
instructions regard-
how to posi-
ing the positioning
tion the
and clamping of the
workpiece
workpiece.
on the saw.
Battery
Replace batteries
symbol is
flashing
"– – – –"
The tool is not
appears in
designed to per-
display
form the desired
operation
Bosch Power Tools
2 609 140 572 | (8.9.08)