Baxi MULTIFIT Evacuated Tube Collector Kit Instructions page 34

Evacuated tube collector 10 tube additional pitched roof kit
Hide thumbs Also See for MULTIFIT Evacuated Tube Collector:
Table of Contents

Advertisement

Indication
Parameter / value
0 –
0
1 –
120ºC
2 –
0
3 –
40ºC
4 –
0
5 –
0
6 –
0
7 –
50
8 –
1,0
9 –
240
10 –
1
11 –
0
12 –
6
13 –
3
Start temperature for the frost protection function
14 –
0
15 –
5
16 –
0
Glycol types (point 6):
0
Anro
1
IIexan E, Glythermin
2
Antifrogen L
3
Antifrogen N
4
IIexan E
5
IIexan P
34
© Baxi Heating UK Ltd 2011
Press
or
up or down to the required sub function.
The icon will flash, press
select the function. Reset by pressing
or
increase/decrease values. Press
and
appears,
ok?
press
to confirm and
disappears.
Description
Collector protection
Start temperature for the collector protection
Re-cooling function (only when collector
protection is on)
Target temperature for the storage after
collector protection activity
Time controlled circulation with
tube collectors
Solar gain off/on
Glycol types (see table below)
Glycol percentage
Volume flow: Litre per impulse - flow meter
Time controlling in s
Storage priority
Frost protection on/off
Sensor assignment - Frost protection
Select cooling thermostat
or temperature differential controller
Auxiliary heating sensor assignment
System configuration
6
7
8
9
10
to scroll
14.0
to
14.7
Menu "Basic adjustment"
for
Adjustment and changes in this menu must be carried out only
by a competent installer or service engineer.
Incorrect adjustments may adversely affect the function of
controller and solar primary system.
ok?
To avoid accidental changes in menu "Basic adjustment", it is
not editable in normal functioning but has only a display
function. To be able to carry out any changes, this menu must
be chosen within the first minute after switching on the
appliance. The basic adjustment menu is 'blocked'
automatically one minute after switching on if the menu is
not accessed.
110..150ºC
5% - steps
0,5 ... 25 I/I
0,5l - steps
-20ºC ... +7ºC
1 = cooling
2 = heating
Tyfocor L5.5 - supplied
Dowcal 10
Dowcal 20
Dowcal N
Tyfocor LS
Commissioning of solar controller
Value
Factory
range
set-up
0 = off
N/A
1 = on
N/A
0 = off
N/A
1 = on
30..90ºC
N/A
0 = off
0 = off
1 = on
0 = off
0 = off
1 = on
0...10
0
0 ... 100%
50
1.0
30...480
240
1...2
1
0 = off
N/A
1 = on
1...6
N/A
N/A
0 = off
2
1...6
5
0...4
0
For correct operation of the system, Baxi
recommend the settings shown above.
Baxi
recommend
N/A
N/A
N/A
0
1
10
100
1.0
240
1
2
5
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

5130243

Table of Contents