Baxi MULTIFIT Evacuated Tube Collector Kit Instructions page 18

Evacuated tube collector 10 tube additional pitched roof kit
Hide thumbs Also See for MULTIFIT Evacuated Tube Collector:
Table of Contents

Advertisement

90°
80°
70°
60°
West
S.W.
less than optimum by
Fig. 19
170mm
Fig. 20
18
© Baxi Heating UK Ltd 2011
North
Angle of tilt
90°
80°
70°
60°
50°
50°
40°
40°
30°
30°
20°
20°
10°
10°
South
0-5%
5-10%
170mm
200mm
200mm
120mm
10.0
10.4
Ensure the sealing washer provided is inserted between the
male and female connections. All connecting pipe work and
fittings must be of a suitable metal; either copper, brass or
stainless steel. Soft soldered joints must not be used. Any seals
or sealing compounds must be resistant to temperatures of up
to 200°C and be resistant up to a 50% glycol/water mix.
When tightening the connections, always apply counter-
East
pressure with a wrench or another spanner to prevent
damage.
10.5
The collector is suitable for angles between 0 - 90°.
S.E.
The roof aspect should ideally face South, however
orientations between 30° East and 40°West of South are
acceptable. Fig. 19 shows the efficiency loss for varying angles
of inclinations and roof orientation (Portrait & Landscape).
10-20%
10.6
The Baxi Solarflo
the supplied fluid. Top-ups cannot be made with water, only
use the fluid supplied (Tyfocor LS). Systems found to have
lower glycol concentrations will not be covered by the
warranty.
10.7
Under no circumstances should the collector be fitted where it
overhangs any part of the roof structure.
Minimum clearances must also be adhered to for servicing and
or replacement of parts (see Fig. 20).
Site Requirements
Connections
Collector inclination for Pitched Roof Mounting
Solar fluid
collector tubes MUST be protected with
TM
Collector location