Baxi MULTIFIT Evacuated Tube Collector Kit Instructions page 24

Evacuated tube collector 10 tube additional pitched roof kit
Hide thumbs Also See for MULTIFIT Evacuated Tube Collector:
Table of Contents

Advertisement

Compression
Elbow
Copper Tail
Fig. 32
24
© Baxi Heating UK Ltd 2011
11.0
Installation of solar collector
11.6
Fitting the Connection Kit (Fig. 32)
1. Do not remove pipe clip.
2. Ensure clip is in the position shown.
3. Insert brass adaptor fully.
4. Push pipe clip in fully and check that the brass adaptor is
correctly retained..
5. Fit the sensor pocket to the compression elbow.
6. Fit compression elbow with sensor pocket and tighten the
union nut.
7. Fit the copper tail ensuring the pipe clip is in the open
position.
8. Push pipe clip in fully and check that the copper tail is
correctly retained.
9. Fit the air bleed fitting to the compression elbow.
10. Fit compression elbow and tighten the union nut.
Brass Adaptor
Compression Elbow
with Sensor Pocket