Baxi MULTIFIT Evacuated Tube Collector Kit Instructions page 21

Evacuated tube collector 10 tube additional pitched roof kit
Hide thumbs Also See for MULTIFIT Evacuated Tube Collector:
Table of Contents

Advertisement

600 - 1100mm (20 tubes)
800 - 1400mm (30 tubes)
See Fig. 22 for Landscape Orientation Dimensions
Fig. 25
Fig. 26
Side Rail
Fig. 27
© Baxi Heating UK Ltd 2011
11.0
11.4
NOTE: The application for fixing the lower and upper mounting
brackets are the same.
1. Determine location for lower mounting brackets. Remove
sufficient tiles to give access for fixing the mounting brackets to
the roof structure. Additional noggins may be required (Figs. 18
& 26).
2. Attach lower mounting brackets to roof ensuring the correct
centres and alignment to roof aspect for your orientation is
used (portrait or landscape) (Fig. 25).
3. The mounting brackets are designed to be formed by hand
to the shape of your tiles/slates. Form the mounting brackets to
the correct shape (Figs. 25 and 26).
4. Replace roof tiles/slates.
5. Secure side rails to lower mounting bracket.
6. Determine location for upper mounting brackets. Remove
Noggin
sufficient tiles to give access for fixing the mounting brackets to
the roof structure. Additional noggins may be required (Figs. 18
& 26).
7. Attach upper mounting brackets to roof ensuring the correct
centres and alignment to roof aspect for your orientation is
used (portrait or landscape) (Fig. 25).
8. The mounting brackets are designed to be formed by hand
to the shape of your tiles/slates. Form the mounting brackets to
the correct shape (Figs. 25 & 26).
Form mounting bracket
by hand to suit Tile
9. Replace roof tiles/slates.
Shape and Noggin
10. Secure side rails to upper mounting brackets.
Installation of solar collector
Sloping Roof Kit (Portrait/Landscape)
21