Resistance Table for Frost Protection Indoor and Outdoor Temperature Sensors
Temp.
Resistance
F
k
-19
181.400
-18
171.400
-17
162.100
-16
153.300
-15
145.000
-14
137.200
-13
129.900
-12
123.000
-11
116.500
-10
110.300
-9
104.600
-8
99.130
-7
94.000
-6
89.170
-5
84.610
-4
80.310
-3
76.240
-2
72.410
-1
68.790
0
65.370
1
62.130
2
59.080
3
56.190
4
53.460
5
50.870
6
48.420
7
46.110
8
43.920
9
41.840
10
39.870
11
38.010
12
36.240
13
34.570
14
32.980
15
31.470
16
30.040
17
28.680
18
27.390
19
26.170
48
Temp.
Resistance
F
k
20
25.010
21
23.900
22
22.850
23
21.850
24
20.900
25
20.000
26
19.140
27
18.130
28
17.550
29
16.800
30
16.100
31
15.430
32
14.790
33
14.180
34
13.590
35
13.040
36
12.510
37
12.000
38
11.520
39
11.060
40
10.620
41
10.200
42
9.803
43
9.420
44
9.054
45
8.705
46
8.370
47
8.051
48
7.745
49
7.453
50
7.173
51
6.905
52
6.648
53
6.403
54
6.167
55
5.942
56
5.726
57
5.519
58
5.320
Temp.
Resistance
F
k
59
5.130
60
4.948
61
4.773
62
4.605
63
4.443
64
4.289
65
4.140
66
3.998
67
3.861
68
3.729
69
3.603
70
3.481
71
3.364
72
3.252
73
3.144
74
3.040
75
2.940
76
2.844
77
2.752
78
2.663
79
2.577
80
2.495
81
2.415
82
2.339
83
2.265
84
2.194
85
2.125
86
2.059
87
1.996
88
1.934
89
1.875
90
1.818
91
1.736
92
1.710
93
1.658
94
1.609
95
1.561
96
1.515
97
1.470
Temp.
Resistance
F
k
98
1.427
99
1.386
100
1.346
101
1.307
102
1.269
103
1.233
104
1.198
105
1.164
106
1.131
107
1.099
108
1.069
109
1.039
110
1.010
111
0.983
112
0.956
113
0.930
114
0.904
115
0.880
116
0.856
117
0.833
118
0.811
119
0.770
120
0.769
121
0.746
122
0.729
123
0.710
124
0.692
125
0.674
126
0.658
127
0.640
128
0.623
129
0.607
130
0.592
131
0.577
132
0.563
133
0.549
134
0.535
135
0.521
136
0.509

Hide quick links: