Window opening measurements:
27"min. to 42" max. (76.2 cm to 101.6 cm) opening width (A).
20" min. (50.8 cm) opening height (B).
A.27" min. (76.2 cm)
B . 20" min. (50.8 cm)
Through-the-wall installation
The wall opening measurements should be:
Height (A): 17 ¼" plus twice thickness of wood used to build
frame
Width (B): 26 ¼"
Depth (D): 4" minimum to 8" maximum.
A
A. 17 ¼"
B. 26 ¼"
A
B
C
B
D
C
C. Wood thickness
D. 4" minimum to
8" maximum.

Electrical Requirements

Ground wire must be connected to ground screw located in lower
right corner of air conditioner when air conditioner is in cabinet.
The electrical ratings for your air conditioner are listed on the
model and serial number (nameplate) label. The model and serial
number label is located behind the front panel on the flange below
the control panel area.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power supply
cord
Wiring requirements
CP15
CP18 / CP24
"
(0.6 cm)
4
115-volt (103.5 min. - 126.5 max.)
0-12 amps
15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only.
230-volt (207 min. - 253 max.)
0-12 amps
15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only.