Friedrich CP15F10 Service And Parts Manual

Friedrich CP15F10 Service And Parts Manual

R410a models compact programmable
Hide thumbs Also See for CP15F10:

Advertisement

Service & Parts Manual – R410A Models
Compact Programmable
CP-15-18-24-ServParts (05-10)
Model
2010

Advertisement

Table of Contents
loading

Summary of Contents for Friedrich CP15F10

  • Page 1 Service & Parts Manual – R410A Models Compact Programmable CP-15-18-24-ServParts (05-10) Model 2010...
  • Page 2 TECHNICAL SUPPORT CONTACT INFORMATION FRIEDRICH AIR CONDITIONING CO. Post Office Box 1540 · San Antonio, Texas 78295-1540 4200 N. Pan Am Expressway · San Antonio, Texas 78218-5212 (210) 357-4400 · 877-599-5665 x 846 · FAX (210) 357-4490 Email: tac@friedrich.com www.friedrich.com...
  • Page 3: Table Of Contents

    Table Of Contents Unit Identification ... 2 Electrical Data ... 3 Specifications ... 4 How to Operate the Air Conditioner with Remote Control ... 5 Method of Charging/Repairs ... 6 Compressor Replacement ...7 Troubleshooting ... 8-10 Wiring Diagrams for 2010 Model ... 11 Exploded View of Parts for 2010 Model ...
  • Page 4: Unit Identification

    Unit identification COMPACT PROGRAMMABLE 3rd and 4th Digit - Approximate BTU/HR (Cooling) Heating BTU/Hr capacity listed in the Specification/Performance Data Section RAC Serial Number Identification Guide Serial Number Decade Manufactured Year Manufactured Month Manufactured A=Jan D=Apr G=Jul B=Feb E=May H=Aug C=Mar F=Jun J=Sept...
  • Page 5: Electrical Data

    Be sure that branch circuit or general purpose outlet is grounded. Ground wire must be connected to ground screw located in lower right corner of air conditioner when air conditioner is in cabinet. (CP 14, 18, 24) Receptacle The field supplied outlet must match plug on service cord and be within reach of service cord.
  • Page 6: Specifications

    Permissible Excessive Operating Pressure for the Suction Side ( P S I ) Dimension (L/W/H)( inch ) Dimension of Package (L/W/H)( inch) Net Weight /Gross Weight ( LBS ) Refrigerant Charge ( OZ ) CP15F10 CP18F30 CC05103400 CC05103410 COOLING COOLING...
  • Page 7: How To Operate The Air Conditioner With Remote Control

    1º until it reaches 64°F (18°C). To set Timer for a 1- to 24-hour delay before air conditioner is turned o (air conditioner must be On): 1. Press TIMER. Indicator light on air conditioner control panel will ash.
  • Page 8: Method Of Charging/Repairs

    method of charging / repairs The acceptable method for charging the RAC system is the Weighed in Charge Method. The weighed in charge method is applicable to all units. It is the preferred method to use, as it is the most accurate. The weighed in method should always be used whenever a charge is removed from a unit such as for a leak repair, compressor replacement, or when there is no refrigerant...
  • Page 9: Compressor Replacement

    comPreSSor rePlacement recommended procedure for compressor replacement WARNING RISK OF ELECTRIC SHOCK Unplug and/or disconnect all electrical power to the unit before performing inspections, maintenances or service. Failure to do so could result in electric shock, serious injury or death. Be certain to perform all necessary electrical and refrigeration tests to be sure the compressor is actually defective before replacing.
  • Page 10: Troubleshooting

    coolinG onlY room air conditionerS: troUBleSHootinG tiPS Fuse blown or circuit tripped Power cord not plugged in System switch in “OFF” position Unit does not run Inoperative system switch or open control board Loose or disconnected wiring at switch, control board or other com- ponents Dirty fi...
  • Page 11 Instruct customer of waiting period Check voltage with unit operating. Check for other appliances on circuit. Air conditioner should be in separate circuit for proper voltage & fused separately Refer to appropriate wiring diagram...
  • Page 12: Troubleshooting

    coolinG onlY room air conditionerS: troUBleSHootinG tiPS Water “spitting” into room Excessive moisture Thermistor short cycles Prolonged off cycles (automatic operation) Outside water leaks Sublimation: When unconditioned saturated, outside air mixes with conditioned air, condensation forms on the cooler surfaces Downward pitch of installation is too steep towards back of unit Restricted coil or dirty fi...
  • Page 13: Wiring Diagrams For 2010 Model

    WirinG diaGram: 2010 model CP15F10 / CP18F30 / CP24F30...
  • Page 14: Exploded View Of Parts For 2010 Model

    VieW and liSt of PartS 2010 model: cP15f10, cP18f30 and cP24f30...
  • Page 15: Parts For 2010 Models

    2010 PartS Model CP15F10 4 Screw 4X20 5 Seal strip 1 6 Seal strip 2 7 Curtain Assemby Left and Right 10 Cabinet Assy 12 Screw M4X8 13 Connect cord 14 Screw M4X5 15 Washer 4 21 Washer 10 22 Fan Blade...
  • Page 16 2010 PartS (continued) Model CP24F30 15 Washer 4 28 Shroud i f i Relay 841-S-1A-D 110/120V Transformer 41X26.5C 63 Filter 67700200 67700154 67700113 67700151 67700128 67700129 67700201 67700202 67700203 67700238 67700155 67700149 67700170 67700205 67700158 67700153 67700206 67700152 67700239 67700157 67700159 67700117 67700208...
  • Page 17: Warranty

    LIMITED WARRANTY ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service.

This manual is also suitable for:

Cp18f30Cp24f30R410a