Avaya P330 User Manual page 186

Manager
Hide thumbs Also See for P330:
Table of Contents

Advertisement

You can modify the Redundancy Global Parameters except for
Redundancy State.
176
Table 21-15. Redundancy Global Parameters (Continued)
Field
Description
When the IP Redundancy Status is enabled, the
state of the backup router may be inactive or
active.
• If active, the backup router detected the
failure of the main router and is currently
forwarding traffic in its place. It answers
ARP requests for the main router,
providing its own MAC address. While the
Redundancy State is active, the backup
router continues to poll the main router to
check for recovery.
• If inactive, no special function is
performed by the secondary router except
polling the main router. While the main
router is operational, the Redundancy
State remains inactive.
The interval in seconds during which the main
router must signal. If the main router does not
signal within this interval, it is considered not
operational.
The polling interval for this router, in seconds. If
the interval is zero, then the router is not
polled.
Avaya P330 Manager User Guide