Installation Requirements - Trane TTD Series Installation Manual

Ttd/ttt series multi-split system condensing unit 18,000-36,000 btuh models 50/60 hz
Table of Contents

Advertisement

1. Copper Tubing
Copper tubing, fittings and
insulation to interconnect the
suction (S) (wide tube) and liquid
(L) (narrow tube) refrigerant lines
between the indoor and outdoor
units can be purchased locally.
It is necessary to purchase the
following items:
Table 2 : For Convertible (MCX), Concealed (MCD) and Hi-Wall (MCW, Frio) Indoor units
Indoor Unit
Item
Deoxidized Annealed
Copper Tube
Foamed Polyethylene
Insulation
Insulated Copper Wire
*On Cooling Mode
Table 3 : For Hi-Wall (MCW, Contura 3G) Indoor units
Indoor Unit
Item
Deoxidized Annealed
Copper Tube
*On Cooling Mode
6

Installation Requirements

- Purchase equal lengths of both
tubes and insulation required.
Cut the appropriate tube lengths,
30 to 40 cm (12 to 16 in.) longer
on each one to deepen vibration
between units. Wall thickness of
copper tube should be 0.8 mm
(0.0314 in.).
Both tubes must be well
insulated with proper insulation
materials.
- The length of wiring will
determine the wire size. See
local codes, refer to section of
electrical installation.
509
O.D.
mm (in)
(L*)
6.35 (1/4)
(S*)
9.52 (3/8)
507
O.D.
mm (in)
(L*)
6.35 (1/4)
(S*)
9.52 (3/8)
512
O.D.
mm (in)
6.35 (1/4)
12.7 (1/2)
Diameter : According to O.D. of copper tube
Thickness : No less than 8 mm (0.3 in)
Length required to make electrical wiring
509
512
O.D.
O.D.
mm (in)
mm (in)
6.35 (1/4)
6.35 (1/4)
9.52 (3/8)
12.7 (1/2)
2. Additional Materials
- Saddles or clamps to hold
refrigerant tubing.
- Insulated clamps or staples
for connecting wire.
See local codes.
- Refrigeration oil and tape
(armored).
- Putty or similar filter.
518
O.D.
mm (in)
mm (in)
6.35 (1/4)
9.52 (3/8)
12.7 (1/2)
15.88 (5/8)
518
524/526
O.D.
mm (in)
6.35 (1/4)
9.52 (3/8)
12.7 (1/2)
15.88 (5/8)
524
O.D.
O.D.
mm (in)
MS-SVN005-EN