NOTE: Procedures and techniques that are considered important enough to emphasize. CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment. WARNINg: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
OPERATION CAUTION: If you need to continuously reset the heater, disconnect power and call Dimplex customer service at Figure 1 1-888-DIMPLEX (1-888-346-7539). Remote Control The fireplace is supplied with a radio frequency remote control. This remote control has a range of approximately 50 feet (15.25 m), it does not have to be pointed at the...
MAINTENANCE Voltage Selector Switch The BFSL33 has 2 voltage options at the time of installa- WARNINg: Disconnect all power coming to fireplace tion, 110/120v and 220/240v. The voltage selector switch is at main service panel before attempting maintenance to be set at the time of installation according to the voltage or cleaning to reduce risk of fire, shock or damage to coming from the power supply.
REMOTE RECEIVER BOARD Carefully lift the partially reflective glass out of the fireplace and set aside in a safe location. AND LOgSET DRIVER BOARD Remove the defective board by removing the 4 REPLACEMENT mounting screws on each corner of the board. Tools Required: Phillips Head Screwdriver Remove the wires attached to the original board and Flat Head Screwdriver...
Disconnect the 3 flicker motor wires, which are Snip the plastic wire ties which secure the internal connected in the terminal block (mounted on the wires together to free up the light harness wires. bracket), together with a capacitor, and remove the www.dimplex.com...
Remove the light strip and harness. Carefully rest the panel inside the lower cavity of the fireplace on its end with the switches near the top. Be Properly orient the new LED strip and reconnect all of careful not to scratch the partially reflective glass. the wiring connections.
Remove the steel curtains by lifting up on the curtain may be necessary to remove. rod releasing it from the center bracket, then sliding Unplug the log set LED wire harness from unit. the rod out from the side mounting tab, and pulling out. www.dimplex.com...
HIgH TEMPERATURE CUT-OUT RE- Repeat on other side. Remove the 2 screws from the log set retaining plate PLACEMENT along the front of the log set and remove the retaining Tools Required: Phillips Head Screwdriver plate. Flat Head Screwdriver Pull the rear edge of the log set forward by grasping WARNINg: If the fireplace was operating prior to the ember bed by the sides, pull firmly until the rear tab servicing allow at least 10 minutes for light bulbs and...
IMPORTANT: Only handle the log-set by the plastic Remove the 8 screws from the upper air in-take panel ember-bed, not the logs themselves. inside the firebox above the partially reflective glass: 4 on the left and 4 on the right. www.dimplex.com...
wiring connections. NOTE: Log-set fits tightly into firebox. Some force may be necessary to remove. Reassemble in the reverse order as above. Unplug the log set LED wire harness from unit. NOTE: See Helpful Hints Section for reassembly. Loosen the screws on the 2 partially reflective glass SWITCHBOARD REPLACEMENT retaining clips: bottom left side and bottom right side of the rear partially reflective glass panel and turn the...
3 housing mounting tabs above the fan to servicing allow at least 10 minutes for light bulbs and release from the top panel. heating elements to cool off to avoid accidental burning Remove the wire connections from the heater/blower www.dimplex.com...
assembly, noting their original locations Figure 4 NOTE: Using a flat head screwdriver gently pry be- tween the end of the connector and the switch to release the wires. Properly orient the new blower assembly and recon- nect all of the wiring connections. Reassemble in the reverse order as above.
LED Light Driver Board Log Set Driver Board Internal Access to Hardwired power connections (panel 3-Light LED Strip removed) and Wire harness LOWER COMPONENT AREA (Logset and Partially Reflective Glass Removed) 3-Light LED Strip and Wire harness Flicker Motor Flicker Rod www.dimplex.com...
Page 17
UPPER COMPONENT AREA Heater Assembly with Upper Vent Panel and Partially Reflective Glass Removed UPPER HOUSINg COMPONENTS Heater Assembly Housing with High Limit Cut Out Blower Motor and Element Connections from the on the top of the Housing Panel and Left Side Right Hand Side Element Connections Voltage Selector Switch and Over Temperature...
Log set dim, not glowing Malfunctioning LED’s in Logset Replace Logset or Driver Board Flame Shudder Defective flicker motor Replace flicker motor Light leaking around the log set Log set not positioned properly Check log set for proper fit www.dimplex.com...
Page 19
PROBLEM CAUSE SOLUTION Heater Heater is not turning off Improper operation Refer to Operation Section Defective Remote Switchboard Replace Remote Switchboard Malfunctioning Wall Controls Refer to Individual Wall Control operating instructions Defective Remote Control Receiver Replace Remote Control Receiver, initialize with Re- mote Control Heater is not turning on Improper operation...