LISTINGS AND CODE APPROVALS The BF series fireplaces have been tested in accordance with the UL 2021 and CSA C22.2 No. 46 standards for fixed and location-dedicated electric room heaters. MODEL SPECIFICATIONS Model Descriptio Voltage Volts Number 33” 120/120/208/ BF33STP Standard 33”...
SECTION A: FRAMING MODEL BF33STP/DXP 15.0” 33.5” BF39STP/DXP 16.0” 39.5” Rough-in framing dimensions This fireplace is a zero clearance design. No combustibles can be placed on the top surface of the fireplace. Combustibles may be installed to the edge of the unit. Four mounting flanges on the sides of the unit are provided to facilitate installation.
VOLTAGE SELECTOR SWITCH LOCATION IMPORTANT: Ensure that the incoming power supply voltage matches the setting of the voltage selector switch. NOTE: The voltage selector switch is located inside the exhaust panel on the top right hand corner. CAUTION: When changing the voltage selector switch from 240 volts to 120 volts ensure that the power supply is turned off.
SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) IMPORTANT: The unit is factory configured for 208/240 volt operation NOTE: Use 3 conductor wire with ground (4 wires total) from the power supply (breaker panel) to the junction box on the unit. NOTE: All wiring must be completed prior to installing the unit.
SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) IMPORTANT: The unit is factory configured for 208/240 volt operation NOTE: Use 2 conductor wire with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit. NOTE: All wiring must be completed prior to installing the unit.
Page 8
SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) (NO HEAT INSTALLATION) IMPORTANT: The unit is factory configured for 208/240 volt operation NOTE: Use 2 conductor wire with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit.
SECTION D: MAIN POWER WALL SWITCH WIRING OPTIONS MAIN POWER WALL SWITCH WIRING NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit you must have the following wires installed: 1. A 3 conductor wire with ground (4 wires total) from the power supply panel to the main switch wall box.
Page 10
240 VOLT MAIN WALL SWITCH WIRING DIAGRAM WHITE - N WHITE – N 240 V RED – L2 RED – L2 POWER SUPPLY WALL SWITCH BLACK – L1 BLACK – L1 (BREAKER PANEL) GROUND - G GROUND - G...
MAIN POWER WALL SWITCH WIRING NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have the following wires installed: 1. A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box.
Page 12
120 VOLT MAIN WALL SWITCH WIRING DIAGRAM WHITE - N WHITE – N RED – L2 120 V POWER BLACK – L1 SUPPLY (BREAKER WALL PANEL) BLACK – L1 SWITCH GROUND - G GROUND - G...
MAIN POWER WALL SWITCH WIRING NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have the following wires installed: 3. A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box.
Page 14
120 VOLT MAIN WALL SWITCH WIRING DIAGRAM NO HEAT INSTALLATION WHITE - N WHITE – N RED – L2 120 V POWER Wire Nut BLACK – L1 SUPPLY (BREAKER WALL BLACK – L1 PANEL) SWITCH GROUND - G GROUND - G...
SECTION E: HEATER WALL SWITCH AND WALL THERMOSTAT WIRING OPTIONS HEATER WALL SWITCH WIRING NOTE: Before installing the unit complete the following: 1. Install main power connection with appropriate voltage as per Section C or Section D. 2. Install a 2 conductor wire with ground (3 wires total) from the heater switch wall box to the junction box on the unit.
Page 16
HEATER WALL SWITCH WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION) RED – 2 WALL RED – 1 SWITCH GROUND - G...
WALL MOUNTED THERMOSTAT WIRING NOTE: Before installing the unit complete the following: 1. Install main power connection with appropriate voltage as per Section C or Section D. 2. Install a 2 conductor wire with ground (3 wires total) from the thermostat wall box to the junction box on the unit.
Page 18
WALL MOUNTED THERMOSTAT WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION) CONNECT GROUND TO WALL BOX RED – 2 WALL RED – 1 THERMOSTAT GROUND - G...
FLAME OVERRIDE SWITCH WIRING NOT AVAILABLE WITH NO HEAT INSTALLATION NOTE: The fireplace can be wired to have a wall switch operate the heater independent of the flame NOTE: Before installing the unit complete the following: 1. Install main power connection with appropriate voltage as per Section C or Section D.
Page 20
FLAME OVERRIDE WALL SWITCH WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER C0NNECTION) NOT AVAILABLE WITH NO HEAT INSTALLATION BLUE – 4 WALL BLUE – 3 SWITCH GROUND - G...