NOTE: Procedures and techniques that are considered important enough to emphasize. CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment. WARNING: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
“Flame Speed Down” button on the remote CAUTION: If you need to continuously reset the heater, control (Figure 3). unplug the unit and call Dimplex North America Limited at “ COD” will appear in place of the sleep timer digits.
When b is higher then A the heat will come on. To turn the heat off, lower the b so that it’s setting is lower then the A. The default temperature setting is 72°F (22°C). NOTE: When using the remote control the heater runs www.dimplex.com...
POWER CORD REPLACEMENT Figure 5 Tools Required: Philips head screwdriver Needle-nose pliers Flat Head Screwdriver WARNING: If the log grate was operating prior to ser- vicing, allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. WARNING: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.
Receiver Housing. (Figure 6) Remove the housing being careful not to add any strain to the wires connecting to the switches. Transfer the wire connectors from the terminals on the original board to the same location on the replacement On/Off Switch board. www.dimplex.com...
then push the switch outward. Alternatively, a flat head screw driver can be used to press the each mounting tab down individually and pushing the switch out, alternating sides until the switch is released from its position. Replace the original switch with the new switch, ensur- ing the correct orientation.
If log does not work, LED defective- replace Log Ember Bed dim, not glowing Loose Connection Check wiring connections Defective Ember Bed Replace Ember Bed Defective Remote Control Receiver Replace Remote Control Receiver Flame Shudder Defective flicker motor Replace flicker motor www.dimplex.com...
Page 11
PROBLEM CAUSE SOLUTION Heater Heater is not turning Off Improper operation Refer to Operation Section Defective Remote Control Receiver Replace Remote Control Receiver. Initialize to Re- mote Control. Heater is not turning On Improper operation Refer to Operation Section Loose wiring Check wiring connections Defective heater assembly Replace heater assembly...