Capacitor
Heater On/Off
switch
14
Dimmer Control Board
Terminal Block
Switch Housing Interior View
Main Power
3 Position switch
"P2" - Connects to the
Potentiometer
"P" - Connects to the Terminal Block
"P1" - Connects to the
Potentiometer
"L" - Connects to Upper Lights
Connects to Capacitor and Flicker Motor
Connects to the Lower Light Assembly and the
Remote Control Receiver Board
Connects to Capacitor and Flicker Motor
Empty
Connects to the "On" side of the Heater switch
and the Lower Light Assembly
Connects to Flicker Motor
Connects to Thermostat
Connects to the Terminal Block and the High
Temperature Cutout
Connects to switch Output on Remote Control
Receiver Board
Power Cord
Connects to the "L" on the Remote Control
Receiver Board
www.dimplex.com