Information regarding design and operation
Collector supports – angle of installation α 25 to 50°
C
A
A Base rail
B Adjustable support
C Collector support
80
Ø 11
50
12
Base rail hole dimensions
Ballast and max. load on the substructure
Calculation in accordance with DIN 1055-4, 3/2005 and DIN 1055-5,
7/2005.
Two foot support slabs each A and B are required respectively for each
collector.
Determining the collector row clearance z
At sunrise and sunset (when the sun is very low), shading cannot be
avoided when collectors are arranged behind one another. To keep
the reduction in yield within acceptable parameters, observe specific
row clearances (dimension z) in accordance with VDI
Directive 6002-1. When the sun is at its highest on the shortest day of
the year (21.12.), the rows at the back should be free of shading.
The angle of the sun β (at midday) on 21.12. must be used to calculate
the row clearance.
VIESMANN
110
B
50°
45°
40°
35°
30°
25°
(cont.)
A
For calculating the distance z between collector rows, see next chap-
ter.
A Foot support A
B Foot support B
Vitosol 200-T, type SD
Combination
x
2 m
2
/2 m
2
900/1200
2 m
2
/3 m
2
3 m
2
/3 m
2
1200/1200
Vitosol 200-T, type SP2, Vitosol 300-T, type SP3
Combination
x
2
2
2 m
/2 m
2
2
900/1200
2 m
/3 m
2
2
1200/1200
3 m
/3 m
Note
For the calculation, the Viessmann "SOLSTAT" calculation program is
available at "www.viessmann.com".
In Germany, this angle (dependent upon latitude) is between 11.5°
(Flensburg) and 19.5º (Konstanz).
50°
45°
40°
35°
30°
25°
B
mm y
mm
900/900
620
825
1029
mm y
mm
900/900
622
827
1031
VITOSOL

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitosol 200-fVitosol 300-fVitosol 200-tVitosol 300-t

Table of Contents