Troubleshooting

Chassis diagnostics

Chassis diagnostics are indicated by the chassis LEDs, as shown in
Figure 16: Chassis LEDs

Input Power LED is extinguished

The Input Power LED illuminates to indicate that the switch logic circuitry is receiving proper
voltages. If the Input Power LED is extinguished:
1. Inspect the power cords and connectors. Is the cord unplugged? Is the cord or connector
2. Inspect the AC power source. Is the power source delivering the proper voltage?

System Fault LED is illuminated

The System Fault LED illuminates to indicate that the switch logic circuitry is overheating or
that a POST error has occurred. The System Fault LED is accompanied by a Heartbeat LED
error blink code. If the System Fault LED illuminates, Identify the Heartbeat LED error blink
pattern and take the necessary actions. See
46
Item
Input Power LED (green)
1
Heartbeat LED (green)
2
System Fault LED (amber)
3
damaged?
— Yes - Make necessary corrections or repairs. If the condition remains, continue.
— No - Continue.
— Yes - Continue.
— No - Make necessary repairs. If the condition remains, contact your HP Authorized
Maintenance Provider.