Switch Fabric-Channel Physical-Port - Fortinet 5003A Fabric And Base Backplane Communications Manual

Fortinet fortiswitch brochure
Hide thumbs Also See for 5003A:
Table of Contents

Advertisement

config

switch fabric-channel physical-port

Use this command to change the administrative status of FortiSwitch-5003A fabric channel interfaces
(bring each interface up or down) and configure each fabric channel interface to receive heartbeat
packets from FortiGate-5001A or 5005FA2 fabric channel interfaces.
Syntax
config switch fabric-channel physical-port
edit <interface_name>
end
Variables
edit <interface_name>
heartbeat {disable |
enable}
status {down | up}
Examples
This example shows how to enable the FortiSwitch-5003A board to listen for heartbeat packets on the
interfaces for chassis slots 6, 8, and 10:
96
set
heartbeat {disable | enable}
set
status {down | up}
Description
Enter the name of the FortiSwitch-5003A fabric channel
interface to configure. You cannot configure physical port
settings for a trunk. You can configure physical port settings for
interfaces that have been added to a trunk.
For the fabric channel <interface_name> can be:
• slot-2/1 used to connect the fabric channels of two
FortiSwitch-5003A boards installed in the same chassis.
• slot-3 FortiGate chassis slot 3.
• slot-4 FortiGate chassis slot 4.
• slot-5 FortiGate chassis slot 5.
• slot-6 FortiGate-5140 chassis slot 6.
• slot-7 FortiGate-5140 chassis slot 7.
• slot-8 FortiGate-5140 chassis slot 8.
• slot-9 FortiGate-5140 chassis slot 9.
• slot-10 FortiGate-5140 chassis slot 10.
• slot-11 FortiGate-5140 chassis slot 11.
• slot-12 FortiGate-5140 chassis slot 12.
• slot-13 FortiGate-5140 chassis slot 13.
• slot-14/f8 FortiGate-5140 chassis slot 14 or
FortiSwitch-5003A front panel slot 14/F8.
• f7 FortiSwitch-5003A front panel slot F7.
• f6 FortiSwitch-5003A front panel slot F6.
• f5 FortiSwitch-5003A front panel slot F5.
• f4 FortiSwitch-5003A front panel slot F4.
• f3 FortiSwitch-5003A front panel slot F3.
• f2 FortiSwitch-5003A front panel slot F2.
• f1 FortiSwitch-5003A front panel slot F1.
Enable or disable listening for heartbeat packets from
FortiGate-5001A or 5005FA2 fabric interfaces.
If you enable listening for heartbeat packets on interfaces
added to link aggregation trunks the FortiSwitch-5003A board
can detect if a FortiGate-5001A or 5005FA2 board is no longer
available. You must configure the FortiGate-5001A or 5005FA2
board to send heartbeat packets using the following
FortiGate-5001A or 5005FA2 CLI command:
config system global
end
Bring the interface up or down.
FortiSwitch-5003A and 5003 Fabric and Base Backplane Communications Guide
set fortiswitch-heartbeat enable
FortiSwitch-5003A CLI reference
Default
disable
up
01-30000-85717-20081205

Advertisement