Using the AXlink mini-XLR connector and external 12 VDC power supply (AXT-MLC
and AXW-MLC)
Connect the Central Controller's AXlink connector to the mini-XLR connector and external 12
VDC power supply to the rear panel of the AXT-MLC or AXW-MLC, as shown in FIG. 10.
4-pin mini-XLR connector
2
1
4
1
GND-
2
AXM
FIG. 10 Mini-XLR connector to external 12 VDC power supply and Central Controller wiring diagram

Using AXlink for data and power (AXM-MLC)

Connect the Central Controller's AXlink connector to the AXlink connector on the touch panel for
data and 12 VDC power as shown in FIG. 11.
PWR (+)
AXP
AXM
GND (-)
FIG. 11 AXlink wiring diagram
If you are using power from AXlink, disconnect the wiring from the Central Controller
before wiring the touch panel.

Using AXlink for data with a 12 VDC power supply

Connect the Central Controller's AXlink connector to the AXlink connector on the touch panel and
external 12 VDC power supply, as shown in FIG. 12.
PWR (+)
AXP
AXM
GND (-)
FIG. 12 AXlink and external 12 VDC power supply wiring diagram
10
3
3
AXP
4
PWR+
PWR (+)
AXP
AXM
GND (-)
AXlink connector on the touch panel
12 VDC power supply
PWR (+)
AXP
AXM
GND (-)
AXlink connector on the touch panel
Central Controller
PWR (+)
GND (-)
Central Controller
12 VDC power supply
PWR+
GND-
1
GND-
AXM
2
3
AXP
4
PWR+