Rack-Mount Panel (Axm-Mlc/Pb); Wood Enclosure - panja Black/White LCD Instruction Manual

Black/white lcd mini-touch panels (firmware version g3 or higher)
Table of Contents

Advertisement

2. Carefully insert a flat-blade screwdriver into the release slot on the touch panel's faceplate and
remove the engraved overlay.
3. Lay the touch panel facedown on a soft cloth and remove the screws from the low-profile Back
Box; remove the Back Box and discard.
4. Place the BB-MTP into the cutout and mark the threaded insert positions, as shown in FIG. 5.
5. Remove the BB-MTP and drill four #6-32 insert holes. Then, place a threaded insert (or screw
anchor) into each hole.
6. Disconnect the AXlink connector from the Central Controller.
7. Remove one or more knockouts to accommodate the wiring as required.
8. Thread the incoming AXlink wiring through the BB-MTP knockouts. Refer to the Wiring the
Mini-Touch Panels section on page 8 for pinout descriptions.
9. Fasten the BB-MTP to the plasterboard using the expansion screws supplied with the
enclosure.
10. Connect the AXlink wiring to the touch panel.
11. Test the connection by reconnecting the AXlink connector to the Central Controller. The panel
beeps power-up. Before continuing, disconnect all connections until panel installation is
complete.
12. Fasten the touch panel to the BB-MTP with the #6-32 screws supplied.
13. Place the Decor-style faceplate onto the bezel. You can also secure the Decor faceplate to the
bezel using the four Phillips flathead security screws.
14. Remove the backing from the adhesive tape strips; press the engraved overlay onto the
faceplate. Once attached to the faceplate, the security screws cannot be replaced without
removing the overlay.
15. Reconnect the AXlink wiring to the Central Controller. The touch panel will beep on power-
up.

Rack-mount panel (AXM-MLC/PB)

1. Thread the incoming AXlink wiring through the opening in the equipment rack. Disconnect
the AXlink connector from the Central Controller.
2. Insert the touch panel into the equipment rack. Line up the top-left and bottom-right screw
holes and tighten the #6-32 screws. Then, tighten the bottom-left and top-right screws.
3. Connect the AXlink to the touch panel. Refer to the Wiring the Mini-Touch Panelssection for
more information. The touch panel will beep on power-up.

Wood enclosure

To install the AXW-MLC (/PB) wood enclosure:
1. Thread the incoming AXlink cable to the AXW-MLC (/PB).
2. Disconnect the AXlink connector from the Central Controller that supplies power and data to
the AXW-MLC (/PB).
3. Connect the mini-XLR connector to the AXW-MLC (/PB). Refer to the Wiring the Mini-Touch
Panels for more information.