Connecting beverage lines

1. Connect syrup and water lines, following drawings for appropriate model U155 dispenser. Non-carbonated water line
will be labeled "water".
2. Clean and sanitize beverage lines in accordance with cleaning instructions that follow.
NOTES:
Syrup lines are numbered and correspond to the valves as shown in drawing
above. Valve one is always adjacent to ice tower.
Numbered beverage lines extend out from side of dispenser opposite ice chute.
To start-up and operate dispenser
1. Follow detailed cleaning instructions in service manual before operating dispenser.
2. Follow instructions for beverage line hook-up, and restrictions on ice that can be manually filled into a Follett
dispenser.
3. On units with Follett integral ice-water bath beverage cooling ("B" models) only, slowly pour water into ice-waterbath
area to fill empty bath and submerge coils. Coils are submerged when water starts to flow out overflow drain. DO
NOT SPLASH WATER ON ELECTRICAL BOX. Once filled with water, add ice to bath until ice covers top of
waterbath.
4. For manual load units, remove front drain pan or rear lid and fill storage area with compatible ice.
Follett manual load dispensers can accommodate most cube/cubelet ices up
to 1" square and Follett compressed nugget ice. Crushed, flake, nugget,
bagged or congealed ice cannot be used. Use of these ices can jam dispenser
!
and void warranty. Separate any "waffle-like" sections of cubes before adding
to dispenser. For questions about ice compatibility, call Follett's customer
service group toll-free at (800) 523-9361 or (888) 2-FOLLETT, or (610) 252-7301.
5. Turn power switch located on control box to "ON" position.
6. For automatic fill units, follow detailed instructions in icemaker installation section of installation manual, then turn
icemaker (bin signal) switch(es) located on control box to "ON" position and begin to make ice.
7. When dispenser has at least 6" (155mm) of ice in storage area, press "PUSH FOR ICE" lever or button to ensure
that dispenser is operating properly. NOTE: IF ADDITIONAL START-UP INFORMATION IS NEEDED, CALL