Installing remote icemaker

Correct installation of remote icemaker(s) is critical to proper performance
of icemaker and dispenser.
!
Check bin signal on icemaker control board for 24 volt connection. Switch if
necessary.
Refer to installation manual packed with icemaker for important details on
ice transport tube run, ventilation requirements and other installation
requirements. Failure to comply with instructions will void warranty.
1. Position icemaker in desired location.
2. Push one end of ice transport tube(s) through hole(s) provided in side of dispenser.
3. Route tube into ice tube bracket inside dispenser and engage bracket tabs in holes located in end of ice
transport tube(s). (See drawings below.)
4. Proceed with ice transport tube installation from dispenser to icemaker in compliance with instructions
contained in icemaker installation manual packed with icemaker.
Ice tube retainer bracket
thermostat
**Bracket for right hand unit
shown. On left hand units,
thermostat installed on right
side of bracket (side
opposite dispense tower).
(automatic load units only)
Front view**
1"
2.54 cm
ice tube
Side view
6
ice tube
Tabs in ice tube
retainer bracket
engage holes in ice
tube and hold tube
in place