Raid 6 Arrays; Raid 60 Arrays - Adaptec 5085 Installation And User Manual

Serial attached scsi raid controllers
Hide thumbs Also See for 5085:
Table of Contents

Advertisement

RAID 6 Arrays

A RAID 6 array—also known as dual drive failure protection—is similar to a RAID 5 array
because it uses data striping and parity data to provide redundancy. However, RAID 6 arrays
include two independent sets of parity data instead of one. Both sets of parity data are striped
separately across all disk drives in the array.
RAID 6 arrays provide extra protection for your data because they can recover from two
simultaneous disk drive failures. However, the extra parity calculation slows performance
(compared to RAID 5 arrays).
RAID 6 arrays must be built from at least four disk drives. Maximum stripe size depends on
the number of disk drives in the array.
Disk Drive 1
Disk Drive 2
Disk Drive 3
Disk Drive 4
Disk Drives in Logical Drive

RAID 60 Arrays

Similar to a RAID 50 array (see
protection—is built from eight disk drives configured as two or more RAID 6 arrays, and
stripes stored data and two sets of parity data across all disk drives in both RAID 6 arrays.
Two sets of parity data provide enhanced data protection, and striping improves performance.
RAID 60 arrays also provide high data transfer speeds.
Drive Segment Size
250 GB
(Smallest Disk Drive)
250 GB
Disk Drive 1
Disk Drive 2
400 GB
Disk Drive 3
Disk Drive 4
400 GB
page
93), a RAID 60 array—also known as dual drive failure
Appendix B: Understanding RAID
1 P1 ...
P2
2 P2 ... 449
P1 3 ...
P1
Unused Space = 150 GB
P2 4 ... 500
Unused Space = 150 GB
Based on the drive segment sizes used:
RAID 6 Logical Drive = 500 GB plus
parity (P1 & P2)
94

Advertisement

Table of Contents
loading

Table of Contents