Specifications - Fluke Ti20 User Manual

Thermal imager
Hide thumbs Also See for Ti20:
Table of Contents

Advertisement

Appendix D

Specifications

Thermal
Temperature Range............................................ -10 to 350 C (14 to 662 F)
Detector Type ..................................................... 80 x 60 thermal element focal plane array (FPA)
Accuracy ............................................................. 2 C or 2 % (whichever is greater)
Repeatability ....................................................... 1 % or
1 C ( 2 F) whichever is greater
NETD (Thermal Sensitivity) ................................ 200 mK
Temperature Indication ....................................... 0.1 C or 0.2 F
Optical
Field of View (FOV)............................................. Rectangular. 20 Horizontal x 15 Vertical
Minimum Diameter.............................................. 8.1 mm (0.32 in) at 61 cm (24 in)
Optical Resolution (D:S) ..................................... 75:1 or better
Spectral Range ................................................... 7.5 to 14 microns
Target Sighting.................................................... Single Laser (IEC 825/93 Class II, FDA LFR 1040.10 Class II
Instantaneous Field of View................................ 4.4 mrad
Controls
Focus .................................................................. 61 cm (24 in) to infinity
Temperature Scale ............................................. C or F selectable
Palettes ............................................................... Original, Gray, Rainbow (default), Ironbow, Gray Reverse
Measurement Modes .......................................... Automatic or Manual
LCD Backlight ..................................................... Bright/Dim selectable
Operational
Adjustable Emissivity .......................................... .10 to 1.00 by 0.01
Liquid Crystal Display ......................................... 70.5 mm (2.78 in) x 53.5 mm (2.1 in)
Reflected Background Temperature ................... -50 to 905 C (-58 to 1661 F)
Ambient Operating Temperature ........................ 0 to 50 C (32 to 122 F)
Relative Humidity ................................................ 10 to 90 % noncondensing
Storage Temperature.......................................... -25 to 70 C (-13 to 158 F) without batteries
Storage Capacity ................................................ 50 images
Electrical
Power.................................................................. Rechargeable battery pack (included)
Battery Life.......................................................... Minimum 3 hours continuous use
Battery Charge Time........................................... 2 hours in the Imager, 1 hour in the external charger (or until the green
LED turns on)
Data Transfer ...................................................... USB interface, transfer time 25 sec for 50 images
Storage Device ................................................... Flash Memory
D-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents