Monitoring temperature, humidity, and airflow in data centers - a market in need of measurement
Hide thumbs Also See for 975 AirMeter:

Advertisement

Quick Links

Monitoring temperature,
humidity, and airflow
A market in need of measurement
F r o m t h e F l u k e D i g i t a l L i b r a r y @ w w w . f l u k e . c o m / l i b r a r y
in data centers
Application Note
Using a Fluke Ti20 Thermal Imager and a
Fluke 975V AirMeter
protect their servers by monitoring envi-
ronments in rented data centers.
The international law firm
depicted in this story owns no
data centers, despite the large
amount of data it stores and
retrieves. Like many other high-
tech companies, it rents space for
its servers in data centers owned
by others. "The sites we use are
just hosts," says the law firm's
data center support analyst. "The
racks we have there are ours, but
we rent the environment, power
and the bandwidth."
Each of the firm's offices has
one or two racks of servers in a
local data center to service that
site's needs. In addition, the
company has a centralized U.S.
server location, a secondary cen-
ter for backup and redundancy,
and plans for new locations
overseas.
Fluke instruments used
At present, the analyst uses two
Fluke instruments to monitor the
firm's data centers and the status
of its servers in those centers:
The Fluke 975 AirMeter can
record ten fundamental param-
eters associated with indoor air
quality. Of special importance to
data centers are air temperature,
relative humidity, and airflow (air
velocity). Since servers generate
considerable heat, they must be
cooled to manufacturer-specified
temperatures and subjected to no
more than 45 to 50 percent rela-
tive humidity.
test tool, customers

Advertisement

loading

Summary of Contents for Fluke 975 AirMeter

  • Page 1 Monitoring temperature, humidity, and airflow in data centers A market in need of measurement Application Note Using a Fluke Ti20 Thermal Imager and a Fluke 975V AirMeter test tool, customers ™ protect their servers by monitoring envi- ronments in rented data centers.
  • Page 2 “Blade servers are much more However, “our primary use for arranged front to back. efficient [than traditional serv- these tools is to check what we ers]. We can pack six or seven  Fluke Corporation Monitoring temperature, humidity, and airflow in datacenters...
  • Page 3: Additional Capabilities

    Web access: http://www.fluke.com while the blades themselves ©007 Fluke Corporation. All rights reserved. Specifications subject to change without notice. Printed in U.S.A. 5/007 3034678 A-EN-N Rev A 3 Fluke Corporation Monitoring temperature, humidity, and airflow in datacenters...

This manual is also suitable for:

Ti20975v airmeter