WOLF OUTDOOR GRILLS
Planning Information
For portable applications, Wolf grill carts are designed
specifically to fit grill models OG30, OG36 and OG42 and
the side burner. Model OG54 is designed for built-in appli-
cations only.
Wolf outdoor grills and the burner module are designed
for easy placement into a built-in enclosure. For outdoor
grills, installation in a combustible enclosure requires an
insulating liner. For the burner module, an insulating liner
is not required. The enclosure should be built according
to specifications for your specific installation found on the
following pages. If the burner module is installed next to an
outdoor grill, a minimum of 12"
units on the rotisserie motor side and 2"
side. A rotisserie side conversion kit is available from your
authorized Wolf dealer.
Optional stainless steel accessory doors and drawers are
available for built-in applications.
Grill carts, insulating liners, accessory doors and drawers
are avail able through your authorized Wolf dealer. For local
dealer information, visit the find a showroom section of our
website, wolfappliance.com.
BURNER RATING
GRILL BURNERS
OG30, OG36, OG42, BM13
OG54
SEAR ZONE
OG36, OG42
OG54
ROTISSERIE
OG30
OG36, OG42
OG54
|
76
Wolf Customer Care 800.222.7820
is required between
(305)
on the opposite
(51)
Btu
(kW)
25,000
(7.3)
25,500
(7.5)
25,000
(7.3)
25,500
(7.5)
14,000
(4.1)
16,000
(4.7)
(2) 14,00
(4.1)
ELECTRICAL
ELECTRICAL REQUIREMENTS
GRILLS AND MODULES
Electrical Supply
Service
Receptacle
Power Cord
GAS SUPPLY
3
A gas supply line of
/
"
rigid pipe must be provided to
(19)
4
the outdoor grill or module. If local codes permit, a certified,
1
3
3'
long,
/
"
or
/
"
(.9 m)
(13)
(19)
2
4
connector is recommended to connect the units
female inlet to the gas supply line.
If the outdoor grill is being connected to a whole house LP
supply, the LP gas pressure regulator is not provided. It can
be purchased from your authorized Wolf dealer. For local
dealer information, visit the find a showroom section of our
website, wolfappliance.com.
GAS SUPPLY REQUIREMENTS
NATURAL GAS
Gas Supply Pressure
Min Line Pressure
Max Pressure to Regulator
LP GAS
Gas Supply Pressure
Min Line Pressure
Max Pressure to Regulator
grounded, 120 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type, GFCI
6'
(1.8 m)
ID flexible metal appliance
1
/
" NPT
2
5"
WC
(12.5 mb)
7"
WC
(17.5 mb)
14"
WC, .5 psi
(34.9 mb)
(3.5 kPa)
10"
WC
(25 mb)
11"
WC
(27.4 mb)
14"
WC, .5 psi
(34.9 mb)
(3.5 kPa)