WOLF DUAL FUEL RANGES
Planning Information
When installing against a combustible surface, a minimum
10"
riser is required for a 36" dual fuel range with
(254)
charbroiler or griddle and all 48" and 60" models. Follow all
minimum clearances to combustible surfaces shown in the
illustration on the following page.
It is recommended that you use a Wolf pro ventilation hood
or hood liner with the dual fuel range. If the range is to be
installed without ventilation, a 36"
44"
for charbroiler, from countertop to combustible
(1118)
materials above the range is required. Refer to page 90 for
pro ventilation.
BURNER RATING
SURFACE BURNER
(3 or 5) Large
(1) Small
FEATURE
Charbroiler
Griddle
Double Griddle
French Top
minimum clearance,
(914)
Btu
Btu
(kW)
(kW)
SIMMER
HIGH
950
15,000
(.3)
(4.4)
325
9,200
(.1)
(2.7)
NATURAL
LP
16,000
16,000
(4.7)
(4.7)
15,000
13,000
(4.4)
(3.8)
30,000
26,000
(8.8)
(7.6)
15,000
15,000
(4.4)
(4.4)
ELECTRICAL
Wolf dual fuel ranges have a terminal block that allows for a
3-wire or 4-wire installation.
ELECTRICAL REQUIREMENTS
SINGLE OVEN RANGE
Electrical Supply
Service
Total Amps
DOUBLE OVEN RANGE
Electrical Supply
Service
Total Amps
GAS SUPPLY
3
A gas supply line of
/
"
rigid pipe must be provided to
(19)
4
the range. If local codes permit, a certified, 3'
1
3
/
"
or
/
"
ID flexible metal appliance connector is
(13)
(19)
2
4
recommended to connect the units
the gas supply line.
Wolf natural gas ranges will function up to 10,250'
in altitude without adjustment and LP gas ranges will func-
tion up to 8,600'
. If the installation exceeds these
(2621 m)
elevations, contact your authorized Wolf dealer for a high
altitude conversion kit.
GAS SUPPLY REQUIREMENTS
NATURAL GAS
Gas Supply Pressure
Min Line Pressure
Max Pressure to Regulator
LP GAS
Gas Supply Pressure
Min Line Pressure
Max Pressure to Regulator
grounded, 240/208 VAC, 60 Hz
30 amp dedicated circuit
21
grounded, 240/208 VAC, 60 Hz
50 amp dedicated circuit
42.5
long,
(.9 m)
1
/
" NPT female inlet to
2
(3124 m)
5"
WC
(12.5 mb)
7"
WC
(17.5 mb)
14"
WC, .5 psi
(34.9 mb)
(3.5 kPa)
10"
WC
(25 mb)
11"
WC
(27.4 mb)
14"
WC, .5 psi
(34.9 mb)
(3.5 kPa)
|
wolfappliance.com