Technical Specifications
Maximum Operating Pressure
Primary: 4 bar
Factory Test Pressure
Primary: 6 bar
Maximum Operating Temperature
90°C
Code
Maximum output
Nominal supply
Nominal supply (total)
Nominal supply (per phase)
Dual heating elements *
Total capacity
Primary connection (female BSP)
Dimensions
A
B
C
D
E
F
G
Weight empty
Weight full
* A dual element consists of two elements on a single flange, with a combined output of 4.8 kW at 230 volts
2
3
4
5
6
1
Control Panel
1. Thermometer
5. 3rd stage indicator
2. On/off switch
6. 4th stage indicator
3. 1st stage indicator
7. High temperature overheat indicator
4. 2nd stage indicator
8. Manual reset high limit thermostat
9. Control thermostat
Rear
TER 57
TER 86
00080401
00080801
kW
57.6
86.4
V
amps
250.5
376
amps
83.5
125.3
#
12
18
L
155
155
Ø
2"
2"
mm
80
80
mm
124
124
mm
1134
1134
mm
130
130
mm
610
610
mm
1380
1380
mm
610
610
Kg
102
102
Kg
257
257
7
Front
TER 115
TER 144
00081201
00081601
115.2
144
3 x 400 + N
501
626
167
209
24
30
155
155
2"
2"
80
80
124
124
1134
1134
130
130
610
610
1380
1380
610
610
102
102
257
257
8
9
Right Hand Side
TER 201
TER 259
00079101
00079901
201.6
259.2
876.5
1127
292
376
42
54
250
250
DN100
DN100
80
80
190
190
1060
1060
197
197
752
752
1380
1380
752
752
195
195
545
545
36
38
Need help?