Dimensions in compliance with current standards. Maximum operating conditionsn Domestic hot water performance ACV cannot accept liability for any damage resulting from Boiler specifications incorrect installation or from the use of components or fittings not specified by ACV USER GUIDE...
The boiler is fitted with an expansion chamber with a capacity of: Hydraulic Connections • 12 liter on E-Tech S 160 and 240 models. • 2 x 8 liter on E-Tech S 380 models. 1. Motorised 3-way manual mixer valve If the expansion volume is not sufficient for your needs 2.
If the water mains pressure is greater than 6 bar, a pressure reducer calibrated to 4.5 bar must be fitted. Safety unit The tank safety unit must be ACV approved and calibrated to 7 bar. The valve discharge must be connected to the waste water disposal system.
InstallatIon CONTROL WIRING DIAGRAM : E-TECH S 160 The control circuit is automatically powered from the power circuit. It is also protected by a 3A magneto-thermal circuit breaker. (85 - 60°C) 2.1. 2.2. 1.1. 1.2. (78 - 53°C) B. Blue A ON/OFF switch Bk.
InstallatIon CONTROL WIRING DIAGRAM : E-TECH S 240 The control circuit is automatically powered from the power circuit. It is also protected by a 3A magneto-thermal circuit breaker. (85 - 60°C) 2.1. 2.2. 1.1. 1.2. (78 - 53°C) B. Blue A ON/OFF switch Bk.
InstallatIon CONTROL WIRING DIAGRAM : E-TECH S 380 The control circuit is automatically powered from the power circuit. It is also protected by a 3A magneto-thermal circuit breaker. Booster Light On-Peak Light (85-60)°C) 230v ac 2.1. 2.2. B. Blue Bk. Black Br.
InstallatIon POWER WIRING DIAGRAM : E-TECH S 160 • This appliance must be permanently connected to fixed wiring and must be earthed. POwER CIRCuIT POwER SuPPLY • The wiring must be carried out by a competent The power circuit must be connected using three phase person and in accordance with the current IEE wiring 3 x 400 V + Neutral.
InstallatIon POWER WIRING DIAGRAM : E-TECH S 240 • This appliance must be permanently connected to fixed wiring and must be earthed. POwER CIRCuIT POwER SuPPLY • The wiring must be carried out by a competent The power circuit must be connected using three phase person and in accordance with the current IEE wiring 3 x 400 V + Neutral.
InstallatIon POWER WIRING DIAGRAM : E-TECH S 380 The E-tech S 380 model have an unused resistor. POwER CIRCuIT POwER SuPPLY The power circuit must be connected using three phase 3 x 400 V + Neutral. A Control circuit power supply B Safety switch C Power terminal block K Power relays...
InstallatIon startInG uP FILLING THE HEATING AND DOMESTIC HOT ELECTRICAL SAfETY DEVICES • The boiler must be effectively earthed. WATER CIRCUITS • A box fitted with a magneto-thermal circuit breaker must be fitted on the outside of the boiler. This is to protect the boiler 1.
There is a risk of burns from hot water! RECOMMENDATION ACV recommend that boilers should be serviced at least once a year. This servicing work should be carried out by a competent technician. EN • 12...
descrIPtIon OVERVIEW DESCRIPTION OF OPERATION • Combination boiler (central heating and domestic hot water). THE TANk-IN-TANk CONCEPT • Tank-in-Tank indirect storage type domestic hot water production. The Etech’s series differs from traditional hot water producers in that • The central heating connections are designed so that they can be it has a tank immersed in the primary fluid contained in the outer connected in all three directions, this means that the boiler can be body.
Page 14
descrIPtIon CONTROL PANEL 1 - ON/OFFswitch 2 - Power selection switch 3 - Summer/Winter selector switch 4 - Mano-thermometer 5 - Thermostat adjustable between 60 and 85 °C 6 - Safety thermostat: 7 - Safety indicator light 8 - Control Unit (optional) Control panel 1.
4,5 bar - Secondary circuit: 13 bar Operating temperature - Maximum temperature: 85° C Dimensions E-Tech S 160 & 240 Dimensions E-Tech S 380 DOMESTIC HOT WATER PERFORMANCE E-Tech S 160 E-Tech S 240 E-Tech S 380 Operating at 80°C liter /10' Peak flow at 40 °C...
user GuIde USING THE BOILER 7 - Boiler shutdown indicator light This light is lit when the safety thermostat starts up or when the water pressure in the boiler is too low. LEARNING YOuR wAY AROuND THE CONTROL PANEL 8 - Control Unit Please see the enclosed instructions if you have chosen this option.
user GuIde BOILER ROOM SAfETY VALVE (CENTRAL HEATING) A monthly inspection is recommended: • Keep vents free at all times. Lift the lever on the emptying device for a few seconds to ensure that • Do not store any inflammable products in the boiler room. the safety valve is working properly •...