Gas Line Installation

The Ravelle™ 42 gas fireplace must be connected to the gas line in ac-
cordance with local codes and/or the National Fuel Gas Code, ANSI Z223 .1
(In Canada, the current CAN/CSA B149 .1 installation code) . The gas line
should enter the fireplace on the left side (see diagrams on Pages 11 and
12) . If the gas line enters the unit from the right side, the line will need
to be disconnected to remove the blower . The fireplace comes with a flex
line attached to the supply side of the gas valve . The fitting on the end of
the flex line can receive a 1/2" female iron pipe coupling, a 3/8" male iron
pipe, or a shut-off valve . There is sufficient room to locate the shut-off
valve under the firebox at the end of this flex line, however, local codes
may require the shut-off to be located on the exterior of the fireplace . After
connecting the gas line, all joints in the line and connections at the valve
should be checked for leaks before final positioning of the unit . Conduct a
gas leakage test of the appliance piping and control system downstream
of the shutoff valve in the supply line to the appliance .

Gas Pressure Requirements

A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLI-
ANCES IS IMPROPER GAS PRESSURE!
The most important item to check during the initial installation
and the first thing to check when operating problems occur is
gas pressure!
This fireplace will not function properly unless the required
gas pressure is supplied. See the table on this page for gas
pressure requirements.
Two pressure taps are provided on the fireplace's valve to check gas
pressures . To access the taps remove the two socket head screws to
remove the valve control panel/heat shield . The taps are located below the
on/off/pilot knob (see Figure 32) . The left tap is the inlet (supply) pressure
side . To check inlet pressure (with the fireplace burning) insert a small
flat bladed screwdriver into the tap and turn a half turn counterclockwise .
Cover the tap with the line from a manometer and read the pressure .
Close the tap gently but securely after completing the check . The manifold
(outlet) tap is to the right of the inlet tap . To check manifold pressure (with
the fireplace burning at the high burn setting) insert a small flat bladed
screwdriver into the tap and turn a half turn counterclockwise . Cover
the tap with the line from the manometer and check the pressure . Again
close the tap gently but securely after completing the check . Check the
taps for gas leaks with a gas leak test solution (retighten if necessary) .
If the pressure is not sufficient, make sure the gas supply line is large
enough, the supply regulator is properly adjusted and the total gas load
for the residence does not exceed the amount supplied .
Propane tanks are at pressures that will cause damage to valve com-
ponents . Verify that the tanks have step down regulators to reduce the
pressure to safe levels .
The appliance must be isolated from the gas supply piping system
by closing its equipment shutoff valve during any pressure testing of
the gas supply piping system at test pressures equal to or less than
1/2 psig (3 .5 kPa) .
The appliance and its appliance main gas valve must be disconnected
from the gas supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 psig (3 .5 kPa) .
26
Fuel
Type
Natural
Gas
LP Gas
Figure 32

LP and Natural Gas Supplies

Your Ravelle gas fireplace is equipped from the factory for use with
natural gas only as specified on the Safety / Listing label attached to the
appliance . This appliance can only be operated using propane gas (LP)
if a certified fuel conversion kit provided by Lennox Hearth Products is
installed by a qualified service technician .
Also check the orifice size on the label on the igniter bracket . It must be
the correct size for the fuel and altitude .
Do not run propane tank dry. Running the tank dry may cause a
hazardous condition due to pressure drop in empty tank.
Solid fuel is NOT to be used with this unit.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Inlet Pressure
Desired
Minimum
Maximum
7" WC
5" WC
10.5" WC
11" WC
11" WC
13" WC
SIT Millivolt Gas Valve
Inlet (Supply)
The Manifold
Pressure Tap
(Outlet) Tap
Manifold Pressure
On Hi
On Lo
Fire
Fire
3.5" WC 1.7" WC
11" WC
5.4" WC
TH
TP
TP/TH

Hide quick links: