Framing Dimensions - Lennox Hearth Products RAVELLE 42 Installation And Operation Instructions Manual

Direct-vent signature collection
Table of Contents

Advertisement

INSTALLATION

Framing Dimensions

The dimensions given on this page are minimum framing distances
necessary to maintain safe clearances between the fireplace and com-
bustible materials .
u
If the unit is to be vented horizontally with a 90º elbow right off the
top of the fireplace and directly through an exterior wall, then a hole
10-3/4" (273 mm) square with a center line 42-1/4" (1073 mm) above
the base of the fireplace will accommodate the wall thimble and direct-
vent pipe .
v
The gas line should be routed to the left side of the unit . The access
hole in the fireplace for the gas line is 6-7/8" (175 mm) back from
the front edge and 2-1/8" (54 mm) up from the base of the unit . If the
gas line enters the unit from the right side the piping will need to be
disconnected to remove the blower .
If a wall-mounted on/off switch or thermostat is to be used, these
wires should be routed to the left front of the unit for access to the
fireplace . The wire should be fed through the gas line hole, along the
gas line, to the valve .
w
The electrical power supply wiring should be routed to the right rear
of the unit .
Note: The fireplace may be placed directly on wood or non-combustible
flooring, but NOT on vinyl floor covering or carpet.
Framing Suggestions:
The framing header above the front of the
fireplace should be as narrow front to back as allowable to give maximum
clearance to the direct-vent pipe (i .e . don't use a 6" (152 mm) thick header
when a 4" (102 mm) thick one is allowed) .
A 6" (152 mm) header may need to be notched to accommodate vertical
vent pipe . If the fireplace is going to be horizontally vented directly out
the back, do not place a stud in line with the wall thimble . If a hearth
extension greater than 1" (25 mm) thick is going to be used, the fireplace
and the header must be raised accordingly . See Hearth Extension Con-
siderations for further details .
Insulation
The exterior walls adjacent to the fireplace should be insulated like the
rest of the house, but insulation should not be placed around the fireplace
or vent pipe .
Corner Installations
The dimensions on this page are minimum and show the stand-offs on
the rear corners of the fireplace up against the corner walls .
48"
(1219mm)
Figure 3
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
u
C/L
44-1/2"
(1130mm)
21"
(533mm)
44-1/2"
(1130mm)
v
w
11