Lennox Hearth Products Montecito Installation And Operation Instructions Manual
Lennox Hearth Products Montecito Installation And Operation Instructions Manual

Lennox Hearth Products Montecito Installation And Operation Instructions Manual

Epa wood-burning fireplace dave lennox signature collection

Advertisement

SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it
is recommended that this appliance be fitted
with a firescreen kit. See Page 20 for ordering
information.
WARNINGS
Listed to standards:
ULC-S610 and UL-127
Report No. 307-4084
EPA Cert. No. 537
PIMONTECITO REV. 6 MAY 2010
INSTALLATION AND

OPERATION INSTRUCTIONS

MONTECITO™
EPA Wood-Burning Fireplace
P/N 850,037M REV. K 05/2010
MODEL
MONTE
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and
understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not limited to the fireplace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
Lennox Hearth Products wood-burning fireplaces are designed for use
as a supplemental heater. They are not intended for continuous use
as a primary heat source.
Fireplace, also for use in mobile or
manufactured homes with solid fuel only.
• The fireplace cannot be operated without a door
or firescreen. Consult your dealer to select the
correct replacement door or firescreen.
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fireplace only as described in these
instructions.
WARNINGS
TM

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products Montecito

  • Page 1: Operation Instructions

    Lennox Hearth Products wood-burning fireplaces are designed for use as a supplemental heater. They are not intended for continuous use as a primary heat source.
  • Page 2: Safety Rules And Specifications For Mobile Or Manufactured Home Installation

    WARNING combustible flowing window can block the entrance of air. treatments such as curtains on The Montecito™ fireplace must nearby windows that are of suf- be installed with an outside air IMPORTANT ficient length to be blown in front...
  • Page 3: Table Of Contents

    EPA certification. benefit and enjoyment available from your new fireplace. OPERATING THE FIREPLACE Thank you for selecting a Lennox Hearth Products fireplace as the answer to your home Fuel supplemental heating needs. USE SOLID NATURAL WOOD FUEL ONLY. The...
  • Page 4: Starting And Maintaining A Fire

    10 to 20 minutes amount of creosote on the glass and in the after reloading, depending on the heat and on There is no flue damper in the Montecito™ wood chimney. The combustion air control must be the moisture content of the wood.
  • Page 5: Important Cautions

    When H. Do not burn wood in the area in front of the can prevent chimney fires. If you have a chimney operating the Montecito fireplace, open a grate. fire, follow these steps: nearby window temporarily to check if there I.
  • Page 6: Disposing Of Ashes

    DOOR INSTALLATION are disposed of by burial in soil The door must be installed only when the installation of the Montecito™ fireplace is completed. or otherwise locally dispersed, All you have to do is fit the male part of the hinge, already on the door, to the female part, which they should be retained in the is on the fireplace.
  • Page 7: Facade Installation

    Facade Installation WARNING: THE HEARTH EXTEN- Install the Facade per instructions provided in Fireplace SION IS TO BE INSTALLED ONLY Facade Kit (ordered separately - see Page 20). AS ILLUSTRATED. Framing, Facing And Mantel The crack between the fireplace and the hearth extension must be Safety Metal Strip The construction of the framing, facing, and sealed with a non-combustible...
  • Page 8: Framing Dimensions

    Back Wall of Chase/Enclosure OUTSIDE CHASE FRAMING DIMENSIONS Including Finising Materials if any Corner Installation Fireplace Opening Width 19-19/32” 36-1/4” 921 mm 42” 1067 mm * Zero Clearance From Back 30-1/16” 764 mm Spacer to Wall 13-1/2” 343 mm 77” 1956 mm 37-1/2”...
  • Page 9: Nailing Flanges

    Insulate Joists Same As Ceiling Insulated Chase Construction Storm Collar Roof Support Flashing Draft Stops Attic Radiation Shield Floor Ceiling Firestop NOTE: It is recommended that the Wall chase walls and floor be insulated CTDT in the same manner, using the Termination same insulation, as the rest of the building, below the attic.
  • Page 10: Fireplace Blower

    Maximum length See Figure 14 Figure 15 Noncombustible Facing * The height of the louver must be measured from the base of the Montecito fireplace to the When installing the double outlet system, the middle point of the louver. Drywall...
  • Page 11: Outside Air Kit

    OUTSIDE AIR KIT It is mandatory to install an outside air connec- Rain Cap tion to the Montecito™ wood burning fireplace. The following components are required and are included with the fireplace: Flashing Collar Flashing • Outside air kit (includes 40 inch flex that...
  • Page 12: Chimney System

    Note: Blown or fill type insulation materials must not be in contact with the 2. The Lennox Hearth Products fireplace model MONTE may be installed fireplace or in the enclosure frame as described in ‘’Enclosure’’ section.
  • Page 13: Chimney Installation Instructions

    CHIMNEY INSTALLATION Attic Radiation Shield INSTRUCTIONS Attic Radiation ASHT / S2100 Shield HT6103+ / HT6000+ 1. Cut and frame the holes in the ceiling, floor Solid Packed Pipe Flashing and roof where the chimney will pass (see Figure 21). Use a plumb-bob to line up the center of the holes.
  • Page 14: Offset Chimney Installation

    After reaching the location requiring the elbow, proceed as follows: Air Cooled Chimney Chimney ASHT+ / HT6103+ / S-2100+ / HT6000+ Collar Chimneys Spacer (built 1. Install the first elbow; turn it in the required into flashing) direction. Fasten it to the chimney with the three (3) 1/2”...
  • Page 15 Offset Dimensions Total Height Horizontal Offset Chimney Elbow Offset & One Length Between Elbows Two Lengths Between Elbows 6” Height 8” 12” 18” 24” 36” 48” 8” & 48” 12” & 48” 18” & 48” 24” & 48” 36” & 48” 48”...
  • Page 16: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD OFFSET CHIMNEY INSTALLATION (RSM+ and RSMI30) Chimney AC When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. RSMI45) Note: 45º...
  • Page 17: Glass Care - Replacement

    Glass Replacement and lay it on a clean unabrasive surface. To cutting floor or roof joists (see fireplace dimen- The glass used for the Montecito™ fireplace is replace the gasket, first remove all of the old sions Page 9). a high temperature ceramic glass (1,400° F / gasket and gasket cement.
  • Page 18: Chimney Support Installation

    CHIMNEY SUPPORT INSTALLATION Universal Roof Support 18” (460 mm) This support has three possible uses: 18” (460 mm) 1. For ASHT+ / HT6103+ and S-2100+ / HT6000+, it must be used on a roof to support the chimney. 2. It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.
  • Page 19: Masonry Application Instructions

    INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION Follow these steps: 1- Position the fireplace in its location. Temporarily install the ASHT+ WARNING: Before starting the installation, the masonry chimney elbow on the top of the fireplace and, using a level, mark with an oval must be inspected by a qualified chimney sweep.
  • Page 20: Installation Accessories

    Masonry Chimney Adaptor, 30º, BISUMA30 BISUMA30 Montecito™ Facade Black, MFBK H4843 (for use with TUBINOX liner) Montecito Facade Brushed Nickel, MFBN H4844 Central Forced Air Kit Accessories Montecito Facade Hammered Steel, MFMC H4845 Central Forced Air Kit, Central forced air kit including: blower...
  • Page 21: Chimney Components Lists

    CHIMNEY - PARTS AND COMPONENTS LISTS Fireplace Model MONTE - Approved Venting Components manufactured by Security Chimneys International only. Secure Temp ASHT 1” High Temp. Insulated Stainless Steel Chimney 6” I.D. and 8” O.D., Double-Wall Stainl. Steel, Listed to CAN/UCL-S604 and UL-103HT •...
  • Page 22 CHIMNEY - PARTS AND COMPONENTS LISTS TUBINOX LL Chimney Lining System (AC) Air-Cooled Chimney System* Rigid Stainless Steel Liner For Relining A Masonry Chimney, 6” Diameter 6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior Listed to ULC-S635M, UL-1777 and ULC-S640M at 2100º...
  • Page 23: Replacement Parts

    Coupler for AC Chimney (connects ACZI to fireplace) H3274 Contact an Authorized Lennox Hearth Products dealer to obtain any of these parts. Never use substitute materials not approved by Lennox Hearth Products. Use of non-approved parts can result in poor perfor-...
  • Page 24: Product Reference Information

    Your Dealer's Name _________________________________________________ Your Dealer's Phone Number __________________________________________ Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.

This manual is also suitable for:

Monte

Table of Contents