Seiko ColorPainter V-64S Troubleshooting Manual page 23

Table of Contents

Advertisement

Solution
Solution
Check the Print head height.
(
P.2-44 Change the Print head height)
Confirm that the Print head height is not kept at "HIGH" or "NORMAL".
Adjust the Print head position.
(
P.4-39 [PH TO PH] adjustment procedure)
Adjust the Print head's right and left position.
(
P.4-41 [ADJUST PH R/L] adjustment procedure)
Adjust the Print head's bi-direction position.
(
P.4-34 Adjustment procedure of [BIDIRETION1/2/3])
Refer to "Adjustment of bi-direction position" on page 22 of this Guide.
<Shift of the Print head vertical position>
Adjust the Print head's nozzle position.
(
P.4-36 Adjustment procedure of [NOZZLE POS ADJ])
Bleeding
pattern
Cause
Mismatch of the Print head height
Shift of the Print head position
Shift of the Print head bi-direction position
Shift of the Print head vertical position
Depending on the situation, perform a combination of the solutions below.


Bleeding on the print..."