Regency ® L900 Direct Vent Gas Fireplace; Back-Up Battery Installation (Within Power Module) - Regency LIBERTY L900-LP Owners & Installation Manual

Gas fireplace
Table of Contents

Advertisement

1) Remove the glass door.
a. Release the 2 door latches on the left
and right side at the top of the fi rebox.
Latch Location
Latch
b. Swing the door out from the top and release
the hinges on the left and right side of the
door by lifting them up.
Door
c. Place the door on a soft surface to prevent
scratching.
Regency
®
L900 Direct Vent Gas Fireplace
BACK-UP BATTERY INSTALLATION
(within Power Module)
The 9V battery operates the rear burner under power outage conditions.
The AA battery operates the DC Sparker for lighting the pilot.
2) Loosen the 2 screws that hold the left side
heat shield in place.
3) Lift up and pull out the heat shield slightly
to clear the screwheads and then hang it
on the top bracket (located directly above
the heat shield).
Hinge
Heat
Shield
4) Unplug the power source.
5) Loosen the bottom screw and remove the
top screw from the power module.
Heat
Shield
6) Cut the cable tie that holds together the
wires for the power module and the pull
out the power module.
7) Remove the power module cover by
removing the 2 screws, one on each side.
Bracket
8) Install the 9V battery and the AA battery.
9) Reverse steps 7 to 1.
INSTALLATION
Power
Module
Power Module