INSTALLATION

FLUEING

The Regency
®
Room Sealed System (Horizon-
tal Termination Kit (946-112) and the Vertical
Termination with the Co-linear Flex System in
combination with the REGENCY Room Sealed-
Rear Freestanding Gas Stoves (F37-NG and
F37-LPG) have been approved and listed as
Room Sealed heater systems by Australian
Gas Association.
The Horiz. Termination Kit (946-112) includes
everything required for a straight through the
o
wall installation, or add a 45
elbow for a corner
installation.
IMPORTANT
Read all instructions carefully before starting
the installation. Failure to follow these instruc-
tions may create a fi re or other safety hazard,
and will void the warranty. Be sure to check the
fl ueing and clearance to combustible require-
ments in "Locating Your Regency Gas Stove"
to "Flueing Installation Precaution" sections.
Consult your local building codes before begin-
ning installation.
The location of the termination cap must conform
to the diagrams in the "Exterior Flue Terimination
Locations" section.
See the "Exterior Flue Termination Locations"
section for requirements.
When planning your installation, it will be nec-
essary to select the proper length of fl ue pipe
for your particular requirements. Determine the
minimum clearance to combustibles from the
rear of the unit to the wall. It is also important to
note the wall thickness. Before cutting the fl ue
hole through the wall ensure that ALL fl ue and
termination clearances (see the "Exterior Flue
Termination Locations" section) will be met.
NOTE: Ensure compliance with the outside
fl ue terminal location before cutting hole as
both dimensions must be met.
8
INSTALLATION
PRECAUTIONS
The Regency
Vertical Termination with the Co-linear Flex
System are engineered products that have been
designed and tested for use with the F37-NG,
and F37-LPG. The Regency
voided and serious fi re, health or other safety
hazards may result from any of the following
actions:
1) Installation of any damaged Room Sealed
component
2) Unauthorized modifi cation of the Room
Sealed System
3) Installation of any component part not
manufactured or approved by Regency
Industries Ltd.
4) Installation other than as instructed by
Regency
Warning: Always maintain required
clearances (air spaces) to nearby
combustibles to prevent a fire
hazard. Do not fi ll air spaces with
insulation.

PLANNING YOUR FLUEING INSTALLATION

*If this is an outside corner, the minimum distance between the fl ue and the outside corner is
12" (30cm). See "F" on the diagram in the "Exterior Flue Termination Locations" section.
For corner installation, Restrictor must
be set at 1-1/4" open.
FLUEING
®
Room Sealed System and the
®
warranty will be
®
Industries Ltd.
®
F37 Regency
The minimum clearance requirements between
the outer wall of the fl ue pipe and nearby com-
bustible surfaces is 30mm. Be sure to check
the fl ue termination clearance requirements
from decks, windows, soffi ts, gas regulators, air
supply inlets and public walkways as specifi ed in
the "Exterior Flue Termination Locations" section
and in your local building codes.
The gas appliance and fl ue system
must be fl ued directly to the out-
side of the building, and never be
attached to a chimney serving a
separate solid fuel or gas-burning
appliance.
Each Room Sealed gas appliance must use
its own separate fl ue system. Common fl ue
systems are prohibited.
®
SAFETY PRECAUTIONS
FOR THE INSTALLER
1) Wear gloves and safety glasses for protec-
tion.
2) Exercise extreme caution when using lad-
ders or on roof tops.
3) Be aware of electrical wiring locations in
walls and ceilings.
For straight rear installation, Restrictor
must be set at 1-1/8" open.
Rear Flued Room Sealed Freestanding Gas Heater